Description
The Part Number 779121-01 refers to a PXI Multifunction DAQ unit, specifically the model PXI-6281. This device is categorized under the M Series DAQ and boasts a comprehensive set of features designed to meet a wide range of data acquisition needs.
The PXI-6281 model is equipped with 16 Analog Input Channels and 2 Analog Outputs (AO), making it versatile for various analog signal processing tasks. In addition, it features 24 Digital I/O (DIO) ports, allowing users to handle a significant number of digital signals concurrently. The high resolution of 18 Bits ensures precise measurement and signal representation, enhancing the accuracy of data collected.
With a Maximum Sample Rate of 625 kS/s, this device can swiftly process signals, making it suitable for applications requiring high-speed data acquisition. It comes with NIDAQmx driver software, which provides a straightforward and efficient way to interface with the hardware. Furthermore, it is compatible with Application Development Environments (ADEs) such as LabVIEW and LabWindows/CVI, offering flexibility in programming and customization.
The PXI-6281 requires a Warm-Up Time of 15 minutes before reaching operational stability. To maintain its performance and reliability, it is recommended to undergo a Calibration Period of at least once every 2 years. It operates within a temperature range of 0 °C to 55 °C and should be stored in temperatures ranging from -20 °C to 70 °C. The acceptable Humidity Range for operation is 10% RH to 90% RH (noncondensing), ensuring the device’s durability in various environmental conditions.
| Specification | Detail |
|---|---|
| Part Number | 779121-01 |
| Category | PXI Multifunction DAQ |
| Model | PXI-6281 |
| Description | M Series DAQ (16 Analog Inputs, 24 Digital I/O, 2 Analog Outputs) |
| Analog Input Channels | 16 |
| Analog Outputs (AO) | 2 |
| Digital I/O (DIO) | 24 |
| Resolution | 18 Bits |
| Maximum Sample Rate | 625 kS/s |
| Driver Software | NIDAQmx |
| Compatible ADEs | LabVIEW, LabWindows/CVI |
| Warm-Up Time | 15 minutes |
| Calibration Period | At least once every 2 years |
| Operating Temperature Range | 0 °C to 55 °C |
| Storage Temperature Range | -20 °C to 70 °C |
| Humidity Range | 10% RH to 90% RH (noncond
Question 1: What is the max sample rate of PXI-6281? Question 2: How long is PXI-6281’s warm-up time? Question 3: What is PXI-6281’s calibration period? Question 4: How many AI and DIO ports does PXI-6281 have? Question 5: What driver software does PXI-6281 use? |