The Part Number 780587-24 refers to a PXI Switch identified as the model PXIe-2524. This device is categorized under PXI Switches and is renowned for its versatility and high performance in automated test systems. The PXIe-2524 is designed as a 2 A, Multi-bank Multiplexer, featuring 16 banks of 8×1, 1-wire configurations. This specification enables it to handle a diverse range of signal routing requirements efficiently.
The device showcases an impressive Maximum Switching Current of 2 A and a Maximum Switching Power capacity of either 60 W or 62.5 VA, ensuring it can manage a broad spectrum of power requirements for various applications. In terms of configuration, the PXIe-2524 can be adapted into multiple forms including 16 bank 8×1, octal 16×1, quad 32×1, dual 64×1, and even a 128×1 multiplexer layout, highlighting its flexibility in addressing different system needs.
At its core, the PXIe-2524 employs Electromechanical relays to achieve reliable switching performance. These relays contribute to the device’s RF Performance Bandwidth of less than 10 MHz, a DC Path Resistance of less than 0.8 Ohms, and a Thermal EMF of less than 10 micro-volts, ensuring high-quality signal integrity and minimal signal degradation.
The Relay Operation Time is noted to be typically around 1 ms, with a maximum threshold of 3.2 ms, allowing for swift signal routing. Furthermore, the PXIe-2524 boasts an impressive Life Cycle of Relays rated at 1 x 108 cycles, indicating its longevity and durability for extended use in demanding environments.
Connectivity is facilitated through a
Question 1: What is the maximum switching current of the PXIe-2524? Question 2: How many configuration forms can the PXIe-2524 adapt to? Question 3: What is the relay operation time of the PXIe-2524? Question 4: What type of relays does the PXIe-2524 use? Question 5: What is the life cycle of the PXIe-2524’s relays?
Specification
Detail
Part Number
780587-24
Category
PXI Switches
Model
PXIe-2524
Description
2 A, Multi-bank Multiplexer (16 banks of 8×1, 1-wire)
Maximum Switching Current
2 A
Maximum Switching Power
60 W or 62.5 VA
Multiplexer Configurations
16 bank 8×1, octal 16×1, quad 32×1, dual 64×1, 128×1
Relay Type
Electromechanical relays
RF Performance Bandwidth
< 10 MHz
DC Path Resistance
< 0.8 Ohms
Thermal EMF
< 10 micro-volts
Relay Operation Time
Typical: 1 ms, Maximum: 3.2 ms
Life Cycle of Relays
1 x 108 cycles
Connectors
160 DIN 41612, 160 positions, male connector
Answer 1: 2 A
Answer 2: Multiple, including 128×1 multiplexer
Answer 3: Typically 1 ms, up to 3.2 ms
Answer 4: Electromechanical relays