Description
The product with part numbers 781098-01, 781098-02 features an impressive 16-bit resolution, ensuring high precision in your measurements. It comes equipped with 4 Analog Output Channels, allowing for a versatile range of uses in various applications.
Each channel is capable of a Maximum Sampling Rate of 100 kS/s, providing fast and efficient data output. Additionally, it boasts Channel-to-Channel Isolation, ensuring that signal integrity is maintained across all channels without interference.
The device offers a wide Output Voltage Range of ±10 V, and each channel can deliver an Output Current of up to ±10 mA maximum. When all channels are utilized, the total output current capacity is ±20 mA, catering to a broad spectrum of electrical demands.
Software support is comprehensive, including the LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, and LabVIEW Real-Time Module, providing a rich development environment for various applications. Moreover, the device is compatible with NI CompactDAQ systems (as of NI-DAQmx Version 9.1), enhancing its utility and integration capabilities.
Despite its capabilities, the device remains lightweight at only 5.5 oz., and it operates within a wide Temperature Range of -40 °C to 70 °C, ensuring reliability under extreme conditions. For users looking to enhance their setup, the recommended accessory is the NI-9971 Backshell Kit.
Regarding calibration, the device offers options for NIST accredited calibrations through a 3rd party, as well as basic in-house calibration, ensuring that the device maintains its accuracy and reliability over time.
| Specification | Detail |
|---|---|
| Part Numbers | 781098-01, 781098-02 |
| Resolution | 16-bit |
| Analog Output Channels | 4 |
| Maximum Sampling Rate (per channel) | 100 kS/s |
| Channel-to-Channel Isolation | Yes |
| Output Voltage Range | ±10 V |
| Output Current (per channel) | ±10 mA maximum |
| Total Output Current (all channels) | ±20 mA |
| Software Support | LabVIEW Professional Development System for Windows, LabVIEW FPGA Module, LabVIEW Real-Time Module |
| NI CompactDAQ Support | Yes (as of NI-DAQmx Version 9.1) |
| Weight | 5.5 oz. |
| Operating Temperature Range | -40 °C to 70 °C |
| Recommended Accessories | NI-9971 Backshell Kit |
| Calibration Options | NIST accredited calibrations through a 3rd party; basic in-house calibration |
Question 1: What is the resolution of the NI-9269?
Answer 1: 16-bit
Question 2: How many analog outputs does the NI-9269 have?
Answer 2: 4 channels
Question 3: What is the max sampling rate of the NI-9269?
Answer 3: 100 kS/s
Question 4: What temperature range can the NI-9269 operate in?
Answer 4: -40 °C to 70 °C
Question 5: What is the max output current per channel on the NI-9269?
Answer 5: ±10 mA