Description
The USB-6343 Multifunction I/O Device, belonging to the X Series, is a highly versatile and robust device designed for a wide range of data acquisition and control applications. It comes with multiple part numbers, including 781439-01, 782253-01, 782252-01, and 150199C-01L, offering flexibility in selection based on specific project requirements.
This device is equipped with 16 differential or 32 single-ended analog input channels, providing a broad range of measurement and monitoring capabilities. Its overvoltage protection ensures device safety and data integrity, with ±25 V protection when powered on and ±15 V in off mode, safeguarding against unexpected voltage spikes.
Moreover, the USB-6343 boasts 4 analog output channels with a DAC resolution of 16 bits, enabling precise control and output of analog signals. The maximum sample rate for analog output (AO) reaches up to 500 kS/s, ensuring high-speed data processing and responsiveness. Update rates vary by channel count, achieving up to 900 kS/s for 1 channel and scaling down to 719 kS/s for 4 channels, allowing for simultaneous updates across multiple channels with excellent timing accuracy of 50 ppm of sample rates.
The output range of the device is ±10 Volts, providing sufficient flexibility for a wide variety of applications. Additionally, it operates within a temperature range of 0 °C to 45 °C, and its storage temperature range extends from -40 °C to 70 °C, ensuring reliable performance in various environmental conditions.
| Specification | Details |
|---|---|
| Part Numbers | 781439-01, 782253-01, 782252-01, 150199C-01L |
| Device Type | USB-6343 Multifunction I/O Device |
| Series | X Series |
| Analog Input Channels | 16 differential or 32 single-ended |
| Overvoltage Protection (Powered On) | ±25 V |
| Overvoltage Protection (Off Mode) | ±15 V |
| Analog Output Channels | 4 |
| DAC Resolution | 16 bits |
| Maximum Sample Rate (AO) | 500 kS/s |
| Update Rates (Simultaneous) | 1 Ch: 900 kS/s, 2 Ch: 840 kS/s, 3 Ch: 775 kS/s, 4 Ch: 719 kS/s |
| Timing Accuracy | 50 ppm of sample rates |
| Output Range | ±10 Volts |
| Operating Temperature Range | 0 °C to 45 °C |
| Storage Temperature Range | -40 °C to 70 °C |