Description
The NI 9232 is a highly capable C Series Analog Input module with a part number of 782000-02. This module is designed to handle 3 channels of input, with an impressive input voltage range of -30 V to 30 V. It offers a high sample rate of 102.4 KS/s per channel, ensuring quick and accurate data capture. With a resolution of 24 Bit, it provides high-definition signal processing capabilities.
The NI 9232 is equipped with IEPE signal conditioning, which includes software-selectable AC/DC coupling, making it highly versatile for a wide range of applications. Connectivity options include both BNC and Screw-terminal connections, offering flexibility in system integration. Furthermore, it boasts 60 VDC continuous channel-to-earth ground isolation and 1,000 Vrms surge protection, ensuring the safety and reliability of the module under various operational conditions.
Designed to withstand harsh environments, the NI 9232 operates within a temperature range of -40 to 70 °C and can be stored in temperatures ranging from -40 to 85 °C. Its robust construction is capable of handling vibration levels of 5 grms, 5 g (10 to 500 Hz), further emphasizing its durability and reliability for industrial applications.
Specification | Detail |
---|---|
Part Number | 782000-02 |
Category | C Series Analog Input |
Model | NI-9232 |
Description | NI 9232 3-Ch +/-30V,102.4 kS/s,24 Bit IEPE Analog Input Module,CC |
Channels | 3 |
Input Voltage Range | -30 V to 30 V |
Sample Rate | 102.4 KS/s/channel |
Resolution | 24 Bit |
Signal Conditioning | IEPE, software-selectable AC/DC coupling |
Connectivity | BNC or Screw-terminal |
Isolation | 60 VDC continuous channel-to-earth ground |
Surge Protection | 1,000 Vrms |
Operating Temperature Range | -40 to 70 °C |
Storage Temperature Range | -40 to 85 °C |
Vibration | 5 grms, 5 g (10 to 500 Hz) |