Description
The PXIe-4081 is a high-performance 7½ digit DMM and 1000 V Digitizer, designed to meet a wide range of measurement needs. This device is identified by its part numbers 783130-01 and 154888C-02L, placing it within the category of PXI Multimeters.
The voltage measurement capabilities of the PXIe-4081 span from ±100 mV to ±1000 V, whether DC or AC coupled, making it versatile for a broad spectrum of applications. It also boasts a current range of ±1 µA to ±3 A, suitable for both low and high current measurements. This multimeter offers an impressive sample rate that ranges from 10 Samples per second (S/s) to 1.8 Mega Samples per second (MS/s), ensuring high-speed data acquisition.
Input impedance is rated at 10 MΩ ± 2% in parallel with 90 pF, optimizing the device for a variety of electrical environments. The maximum DC voltage component that can be safely applied is 400 V, providing a safe margin for a range of electrical tasks. Its frequency measurement capabilities cover a range from 15 Hz to 500 KHz, alongside a period measurement range of 2 µs to 66.67 ms, catering to a wide spectrum of frequency-related applications.
The ADC linearity of the PXIe-4081 is exceptional, with accuracy up to 0.5 ppm of reading + 0.5 ppm, ensuring precise and reliable measurements. A warm-up time of 60 minutes is required for the device to operate at its optimum accuracy, ensuring that all components are stabilized and ready for precise measurement tasks.
In summary, the PXIe-4081 emerges as a powerful tool in the domain of PXI Multimeters, offering a range of features from high-accuracy voltage and current measurements to fast sample rates and excellent ADC linearity. It is an ideal solution for professionals seeking a reliable, high-performance measuring instrument.
| Specification | Detail |
|---|---|
| Part Number | 783130-01, 154888C-02L |
| Category | PXI Multimeters |
| Model | PXIe-4081 |
| Description | High-Performance 7 1/2 Digit DMM and 1000 V Digitizer |
| Digits | 7½ |
| Voltage Range | ±100 mV to ±1000 V (DC or AC coupled) |
| Current Range | ±1 µA to ±3 A |
| Sample Rate | 10 S/s to 1.8 MS/s |
| Input Impedance | 10 MΩ ± 2% in parallel with 90 pF |
| Maximum DC Voltage Component | 400 V |
| Frequency Range | 15 Hz to 500 KHz |
| Period Measurement Range | 2 µs to 66.67 ms |
| ADC Linearity | Up to 0.5 ppm of reading + 0.5 ppm |
| Warm-up Time | 60 minutes |
| Calibration