The NI 9247 is a highly versatile C Series Analog Input module, with a part number of 783589-01. This module is designed for precise and high-speed data acquisition, offering 3 Isolated Analog Input Channels. Each channel is capable of a sample rate of 50 kS/s simultaneously, making it suitable for a wide range of applications.
The NI 9247 features an impressive current range of 50 Arms nominal, with the ability to handle up to 100 Arms instantaneous and ±147 Apeak, allowing it to be used in applications involving high current measurements. The module’s connectivity is designed for convenience, featuring direct ring lug based connections for current transformers.
Software compatibility is a key aspect of the NI 9247, with support for NIDAQmx, LabVIEW, LabWindows/CVI, and Visual Basic .NET. This wide range of software compatibility ensures that the module can be easily integrated into existing systems or used in the development of new applications.
In terms of safety and isolation, the NI 9247 provides 480 Vrms of isolation between channels and 300 Vrms to Earth, ensuring safe operation even in environments with high voltage levels. The module is specifically designed for AC measurements only, making it an ideal choice for applications that require accurate AC current measurements.
The module is also designed with durability in mind, weighing 8.75 oz and capable of operating in a wide temperature range from -40 °C to 70 °C. It also has a storage temperature range of -40 °C to 85 °C, ensuring that it can withstand harsh environmental conditions.
Specification | Detail |
---|---|
Part Number | 783589-01 |
Category | C Series Analog Input |
Model | NI-9247 |
Description | NI 9247, 50 A, 24-Bit, 50 kS/s/ch, 3-Ch, AI C Series Module |
Channels | 3 Isolated Analog Input Channels |
Sample Rate | 50 kS/s per channel Simultaneous |
Current Range | 50 Arms nominal, up to 100 Arms instantaneous and ±147 Apeak |
Connectivity | Direct ring lug based for current transformers |
Software Compatibility | NIDAQmx, LabVIEW, LabWindows/CVI, Visual Basic .NET |
Isolation | 480 Vrms between channels, 300 Vrms to Earth |
Measurement Type | AC measurements only |
Weight | 8.75 oz |
Operating Temperature Range | -40 °C to 70 °C |
Storage Temperature Range | -40 °C to 85 °C |
Humidity Range |