The PXIe-5413 is a PXI Arbitrary Waveform Generator with features like 20 MHz frequency, 16 bits, and 800 MS/s sample rate.

In Stock | Ships Today

img

    Description

    The Part Number 784181-01 corresponds to the PXI Arbitrary Waveform Generators category, specifically the Model PXIe-5413. This model is a PXI Waveform Generator with a specification of 20 MHz, 16 bits, 800 MS/s, 1 Channels, 128 MB. It is designed to cover a Frequency Range of up to 20 MHz and has a Step Response Rise Time of 14.8 ns.

    The Arbitrary Waveform Size for this model ranges from 2 samples to 64,000,000 samples, providing a wide range for generating complex waveforms. The User Sample Rate can vary, with digital filter enabled, from 5.6 µS/s to 200 MS/s, and with digital filter disabled, from 3.125 MS/s to 200 MS/s. This flexibility in sample rates allows for precise control over waveform generation.

    The Frequency Step Size is as minute as 2.84 µHz, allowing for extremely detailed frequency adjustments. A total of 8,192 Waveform Points can be utilized, ensuring ample data points for generating accurate waveforms. The device operates with a Reference Clock Frequency of 100 MHz (<±25 ppm) and a Sample Clock Rate of 800 MHz, providing high precision and speed.

    Lastly, the PFI I/O Frequency Range extends from 0 MHz to 25 MHz, offering a broad range of input/output frequencies to accommodate various applications. This model is engineered to meet the needs of users requiring high-speed, accurate waveform generation in a compact PXI module form factor.

    Specification Details
    Part Number 784181-01
    Category PXI Arbitrary Waveform Generators
    Model PXIe-5413
    Description PXIe-5413 PXI Waveform Generator, 20 MHz, 16 bits, 800 MS/s, 1 Channels, 128 MB
    Frequency Range Up to 20 MHz
    Step Response Rise Time 14.8 ns
    Arbitrary Waveform Size 2 samples to 64,000,000 samples
    User Sample Rate (Digital Filter Enabled) 5.6 µS/s to 200 MS/s
    User Sample Rate (Digital Filter Disabled) 3.125 MS/s to 200 MS/s
    Frequency Step Size 2.84 µHz
    Waveform Points 8,192
    Reference Clock Frequency 100 MHz (<±25 ppm)
    Sample Clock Rate 800 MHz
    PFI I/O Frequency Range 0 MHz to 25 MHz
    Maximum Input

    Question 1: What is the frequency range of the PXIe-5413?
    Answer 1: Up to 20 MHz

    Question 2: What is the max sample rate of the PXIe-5413?
    Answer 2: 800 MS/s

    Question 3: How many bits does the PXIe-5413 support?
    Answer 3: 16 bits

    Question 4: What’s the Arbitrary Waveform Size range of PXIe-5413?
    Answer 4: 2 to 64,000,000 samples

    Question 5: What’s the min Frequency Step Size for PXIe-5413?
    Answer 5: 2.84 µHz