Description
The NI-9217 is a C Series Analog Input module designed for precise data acquisition and measurement. It has a part number of 785187-01 listed, with an additional reference of 779592-01 in the description. This module is specialized for 4-Ch RTD, PT100 applications, boasting a 24-bit resolution and a sample rate of 50S/s per channel. The aggregate sample rate is 400 S/s, catering to a wide range of high-precision applications.
The module is compatible with PT100 RTD C sensors and offers flexibility in RTD configurations, supporting both 3- and 4-wire RTD estimations with automatic detection. This ensures accurate and reliable measurements across a resistance range of 0 Ω to 400 Ω. Each channel benefits from per-channel current excitation, enhancing the signal conditioning process for optimal data quality.
Integration capabilities of the NI-9217 are extensive, with support for CompactDAQ, LabVIEW, NI-DAQmx driver software, LabWindows/CVI, and Microsoft Visual C++. This makes the module highly versatile and suitable for a wide range of applications in various industries.
Designed to operate in harsh environments, the module has an operating temperature range of -40 °C to 70 °C and a storage temperature range of -40 °C to 85 °C. It also maintains performance in varying humidity conditions, with an operational range of 10% RH to 90% RH (Non-condensing) and a storage humidity tolerance of 5% RH to 95% RH. These specifications ensure the NI-9217’s reliability and durability in challenging conditions.
Specification | Details |
---|---|
Part Number | 785187-01 (Listed), 779592-01 (In description) |
Category | C Series Analog Input |
Model | NI-9217 |
Description | NI 9217 Spring, 4-Ch RTD, PT100, 24-bit, 50S/s/ch AI module |
Channels | 4 |
Sample Rate | 400 S/s aggregate sample rate |
Resistance Range | 0 Ω to 400 Ω |
RTD Type | PT100 RTD C |
RTD Configuration | 3- and 4-wire RTD estimations with automatic detection |
Signal Conditioning | Per channel current excitation |
Integration | CompactDAQ, LabVIEW, NI-DAQmx driver software, LabWindows/CVI, Microsoft Visual C++ |
Operating Temperature Range | -40 °C to 70 °C |
Storage Temperature Range | -40 °C to 85 °C |
Humidity (Operating and Storage) | 10% RH to 90% RH (Non-condensing, Operating), 5
Question 1: What’s the part number for the NI-9217? Question 2: How many channels does the NI-9217 have? Question 3: What type of sensors does NI-9217 support? Question 4: What’s the max sample rate of NI-9217? Question 5: Can NI-9217 operate in -40 °C? |