Description
The NI-9219 is a versatile and robust module designed for a wide array of applications, featuring four channels that are channel-to-channel isolated, ensuring reliable and accurate measurements across diverse conditions. This module is part of the C Series Analog Input category and comes with various part numbers including 785994-01, 779781-02, and 192496F-01L, with the conformal coating available specifically for part number 779781-02, enhancing its durability and reliability in harsh environments.
It boasts a high-resolution 24-bit data acquisition capability, making it ideal for capturing precise measurements. As a Universal Input Module, it supports a wide range of input types such as strain gages, RTDs, thermocouples, load cells, and powered sensors, providing flexibility for different measurement needs. The NI-9219 is designed for seamless integration with NI CompactDAQ and CompactRIO Chassis, ensuring easy setup and compatibility.
The module offers an impressive estimation range of ±60 V max for voltage and ±25 mA for current, catering to a broad spectrum of industrial applications. Its spring terminal connector type facilitates easy and secure connections. With channel-to-channel isolation rated at 250 Vrms, it ensures the safety and integrity of measurements even in electrically noisy environments.
It supports a maximum sample rate of 100 S/s per channel, sufficient for many types of sensors and signals. The signal conditioning is measurement-specific, tailored to optimize performance and accuracy for each type of input. The module also offers comprehensive isolation options including bank-to-bank, channel-to-channel, and channel-to-earth ground, providing flexibility and enhancing measurement reliability.
The NI-9219 is built to operate in a wide temperature range from -40°C to 70°C, ensuring reliable performance in extreme conditions. It comes with an additional NI 9972 Backshell Connector Kit for enhanced connectivity options. The module is supported by NI-DAQmx driver software, facilitating easy integration with software environments and reducing development time.
Compatible with a
Specification | Detail |
---|---|
Model | NI-9219 |
Part Numbers | 785994-01, 779781-02, 192496F-01L |
Category | C Series Analog Input |
Channels | 4 Ch-Ch isolated |
Resolution | 24-bit |
Type | Universal Input Module |
Connectivity | NI CompactDAQ, CompactRIO Chassis |
Conformal Coating | Part number 779781-02 only |
Input Types | Strain gages, RTDs, thermocouples, load cells, powered sensors |
Estimation Range | ±60 V max for voltage, ±25 mA for current |
Connector Type | Spring Terminal |
Isolation | 250 Vrms Ch-Ch |
Maximum Sample Rate | 100 S/s per channel |
Signal Conditioning | Measurement-specific |
Isolation Options | Bank-to-bank, channel-to-channel, channel-to-earth ground |
Temperature Range | -40°C to 70°C |
Additional Kit | NI 9972 Backshell Connector Kit |
Software | NI-DAQmx driver software |
Supported Development Environments | LabVIEW, LabWindows/CVI, C/C++, C#, Visual Basic .NET |
Analog-to-Digital Converters | Four 24-bit ADCs |
Excitation Current