Description
The National Instruments CB-27 I/O Connector Block, with part number 777100-01, is a device designed to facilitate the connection of analog and digital signals to 27-pin PCMCIA data acquisition products. Manufactured by National Instruments (NI), this connector block requires various accessories for operation, including an installation guide, a reference label for the CB-27, a compatible DAQCard, a computer, both a Number 2 Philips screwdriver and a 1/8 in. flathead screwdriver, specific PCMCIA devices such as the PCMCIA-4350, DAQCard-AO-2DC, DAQCard-500, DAQCard-516, and tie wraps.
To connect the CB-27 to NI PCMCIA-4350 devices, one would use either the PR27-30F or PSH 32-30F cables, ensuring they are properly keyed and inserted. The connector block itself boasts a 30-position right angle connector with ejector ears, and 28 screw terminals, each corresponding to a pin number on the connector, thus simplifying the integration of signals.
The CB-27 is designed to handle a maximum working voltage of ±20 V of GND, and it adheres to stringent safety protocols including EN 61010-1, UL 3121-1, and IEC61010-1, guaranteeing its compliance with international safety standards. Furthermore, it meets the required EMC characteristics with multiple EN certifications, ensuring reliable performance in a variety of electromagnetic environments.
Specification | Detail |
---|---|
Part Number | 777100-01 |
Product Name | National Instruments CB-27 I/O Connector Block |
Manufacturer | National Instruments (NI) |
Required Accessories |
Installation guide, Reference label for the CB-27, DAQCard, Computer, Number 2 Philips screwdriver, 1/8 in. flathead screwdriver, PCMCIA-4350, DAQCard-AO-2DC, DAQCard-500, DAQCard-516, or another PCMCIA DAQ device, Tie wraps |
Compatible Cables | PR27-30F, PSH 32-30F |
Connector | 30-position right angle connector with ejector ears |
Screw Terminals | 28 screw terminals corresponding to pin numbers on the connector |
Maximum Working Voltage | ±20 V of GND |
Safety Protocols | EN 61010-1, UL 3121-1, IEC61010-1 |
EMC Certifications | Multiple EN certifications |
Question 1: What type of cables should one use to connect the National Instruments CB-27 I/O Connector Block to NI PCMCIA-4350 devices, and what are the specific features and safety certifications of the CB-27?
Answer 1: To connect the National Instruments CB-27 I/O Connector Block to NI PCMCIA-4350 devices, one would need either the PR27-30F or PSH 32-30F cables, and the key features of the CB-27 include a maximum working voltage capacity of ±20 V of GND and compliance with safety certifications such as EN 61010-1, UL 3121-1, and IEC61010-1.
Question 2: What accessories and tools are required for the proper operation of the National Instruments CB-27 I/O Connector Block, and what are its voltage limits and safety certifications?
Answer 2: The proper operation of the National Instruments CB-27 I/O Connector Block requires an installation guide, a reference label, a compatible DAQCard, a computer, both a Number 2 Philips screwdriver and a 1/8 in. flathead screwdriver, specific PCMCIA devices, and tie wraps; it can handle a maximum working voltage of ±20 V of GND and is certified with safety standards including EN 61010-1, UL 3121-1, and I
Question 3: What accessories and tools are needed to operate the National Instruments CB-27 I/O Connector Block, part number 777100-01, and how does it ensure compliance with international safety and EMC standards?
Answer 3: One should use either the PR27-30F or PSH 32-30F cables to connect the National Instruments CB-27 I/O Connector Block to NI PCMCIA-4350 devices; the CB-27 features a 30-position right angle connector with ejector ears, 28 screw terminals for easy signal integration, a maximum working voltage of ±20 V of GND, and complies with safety certifications including EN 61010-1, UL 3121-1,
Question 4: What accessories are required to operate the National Instruments CB-27 I/O Connector Block, and what specific PCMCIA devices are compatible with it?
Answer 4: To operate the National Instruments CB-27 I/O Connector Block, part number 777100-01, the required accessories and tools include an installation guide, a reference label for the CB-27, a compatible DAQCard, a computer, both a Number 2 Philips screwdriver and a 1/8 in. flathead screwdriver, specific PCMCIA devices such as the PCMCIA-4350, DAQCard-AO-2DC, DAQCard-500,
Question 5: What type of cables are needed to connect the National Instruments CB-27 I/O Connector Block to the NI PCMCIA-4350 devices, and what are the key features of the CB-27 regarding voltage capacity and safety certifications?
Answer 5: To operate the National Instruments CB-27 I/O Connector Block, the required accessories include an installation guide, a reference label for the CB-27, a compatible DAQCard, a computer, a Number 2 Philips screwdriver, a 1/8 in. flathead screwdriver, and tie wraps, while the specific compatible PCMCIA devices are the PCMCIA-4350, DAQCard-AO-2DC, DAQCard-500, and DAQCard-