Description
The National Instruments cDAQ-9178 CompactDAQ Chassis, with part number 781156-01, is a multifaceted data acquisition system that comprises eight slots for module integration and offers a generous input FIFO size of 127 samples per slot. The maximum sample rate of the chassis is determined by the specific C Series module being used, allowing for tailored performance based on measurement requirements.
Equipped with four 32-bit general-purpose counter/timers, the cDAQ-9178 is capable of a wide range of functions including edge counting, pulse width measurement, and position encoding, among others. It also facilitates the generation of pulses, pulse trains, and square waves, all with adjustable frequencies to suit diverse application needs. Users can access counter sources through hardware-timed digital I/O modules or via two dedicated PFI terminals on the chassis.
Integration with external systems is streamlined through two BNC connectors that enable sharing of clocks and triggers, while the option to use chassis trigger lines or a digital input module (such as the NI-9401 or NI-9411) provides additional versatility. The cDAQ-9178 operates using NI-DAQmx software, which supports an array of development environments like LabVIEW, LabWindows/CVI, C/C++, C#, and Visual Basic .NET, making it adaptable to various programming preferences.
Configuration is simplified with the Measurement & Automation Explorer (MAX) tool, and the presence of three AI timing engines allows the chassis to manage three analog input tasks concurrently, enhancing the throughput and efficiency of measurement systems.
Specification | Detail |
---|---|
Part Number | 781156-01 |
Product Type | National Instruments cDAQ-9178 CompactDAQ Chassis |
Number of Slots | 8 |
Input FIFO Size | 127 samples per slot |
Maximum Sample Rate | Dependent on the C Series module used |
Counter/Timers | Four 32-bit general-purpose |
BNC Connectors | Two for clock and trigger sharing |
Supported Measurements | Edge counting, pulse width, period and frequency measurement, position (encoding) |
Pulse Generation | Pulses, pulse trains, square waves with adjustable frequencies |
Counter Source Access | Hardware-timed digital I/O modules or two chassis PFI terminals |
Trigger Lines | Chassis trigger lines or NI-9401/NI-9411 digital input module |
Software | NI-DAQmx, supports LabVIEW, LabWindows/CVI, C/C++, C#, Visual Basic .NET |
Configuration Tool | Measurement & Automation Explorer (MAX) |
AI Timing Engines | Three, allowing three analog input tasks to run concurrently |
Question 1: What types of functions are enabled by the four 32-bit general-purpose counter/timers on the National Instruments cDAQ-9178 CompactDAQ Chassis?
Answer 1: The four 32-bit general-purpose counter/timers in the National Instruments cDAQ-9178 CompactDAQ Chassis enable functions such as edge counting, pulse width measurement, position encoding, and the generation of pulses, pulse trains, and square waves with adjustable frequencies.
Question 2: What are the capabilities and functions supported by the four 32-bit general-purpose counter/timers included in the National Instruments cDAQ-9178 CompactDAQ Chassis?
Answer 2: The four 32-bit general-purpose counter/timers on the National Instruments cDAQ-9178 CompactDAQ Chassis enable a variety of functions including edge counting, pulse width measurement, and position encoding, in addition to generating pulses, pulse trains, and square waves with adjustable frequencies.
Question 3: What are the capabilities of the National Instruments cDAQ-9178 CompactDAQ Chassis’s four 32-bit general-purpose counter/timers, and how do they facilitate integration with various programming environments?
Answer 3: The National Instruments cDAQ-9178 CompactDAQ Chassis is capable of edge counting, pulse width measurement, and position encoding, among other functions, with eight slots for module integration, four 32-bit counter/timers, and the ability to generate adjustable frequency pulses and pulse trains. It integrates with external systems via two BNC connectors and offers versatility with chassis trigger lines or a digital input module. Furthermore, its software support includes NI-DAQmx, which is compatible with various programming environments such as
Question 4: What are the capabilities and integration features of the National Instruments cDAQ-9178 CompactDAQ Chassis, and how does its software support accommodate different programming environments?
Answer 4: The four 32-bit general-purpose counter/timers of the National Instruments cDAQ-9178 CompactDAQ Chassis are capable of performing a variety of functions such as edge counting, pulse width measurement, and position encoding, and they support the generation of pulses, pulse trains, and square waves with adjustable frequencies. Integration with various programming environments is facilitated by the NI-DAQmx software, which is compatible with LabVIEW, LabWindows/CVI, C/C++, C#, and Visual Basic .NET,
Question 5: What are the specific functions enabled by the four 32-bit general-purpose counter/timers in the National Instruments cDAQ-9178 CompactDAQ Chassis?
Answer 5: The four 32-bit general-purpose counter/timers in the National Instruments cDAQ-9178 CompactDAQ Chassis support a range of functions including edge counting, pulse width measurement, position encoding, and the generation of pulses, pulse trains, and square waves with adjustable frequencies.