Description
The National Instruments cFP-RLY-425 is a high-performance Relay Output Module specifically designed for Compact FieldPoint systems, featuring a part number of 777318-425. This module is manufactured by National Instruments and supports HotPnP (Plug and Play), which simplifies system integration by allowing automatic detection and configuration. With double insulation, the module ensures enhanced safety and reliability.
Equipped with eight non-latching, SPST, normally open relay channels, it can handle a variety of switching tasks. The cFP-RLY-425 can manage an AC input range of up to 250 V and an AC current range between 3-5 A. Additionally, it’s capable of supporting a DC load capacity of up to 125 VDC, with a DC input current range of 0.2-5 A. It boasts a significant switching power of up to 750 VA or 90W and can perform operations at a maximum switching frequency of 0.5 Hz.
The module’s design ensures it can handle a minimum load of 1 mA at 5 VDC, and it’s built to last with an expected life of 2 x 107 mechanical operations. The cFP-RLY-425 is an essential component for industrial applications that require robust and reliable switching capabilities.
Specification | Detail |
---|---|
Part Number | 777318-425 |
Product Name | National Instruments cFP-RLY-425 Relay Output Module for Compact FieldPoint |
Manufacturer | National Instruments |
Module Type | Relay Output Module for Compact FieldPoint |
HotPnP (Plug and Play) | Supported |
Insulation | Double |
Number of Relay Channels | 8 non-latching, SPST, normally open |
AC Input Range | 250 V |
AC Current Range | 3-5 A |
DC Load Capacity | Up to 125 VDC |
DC Input Current Range | 0.2-5 A |
Switching Power | Up to 750 VA or 90W |
Switching Frequency | Maximum 0.5 Hz |
Minimum Load | 1 mA at 5 VDC |
Expected Life | 2 x 107 mechanical operations |
Question 1: What are the specifications and capabilities of the National Instruments cFP-RLY-425 Relay Output Module designed for Compact FieldPoint systems, including its AC and DC input ranges, switching power, and maximum switching frequency?
Answer 1: The National Instruments cFP-RLY-425 Relay Output Module supports an AC current range between 3-5 A and a DC input current range of 0.2-5 A.
Question 2: What is the maximum AC voltage and current range that the National Instruments cFP-RLY-425 Relay Output Module can handle for Compact FieldPoint systems?
Answer 2: The National Instruments cFP-RLY-425 Relay Output Module for Compact FieldPoint systems features HotPnP capability, double insulation for safety, eight non-latching SPST normally open relay channels, an AC input range up to 250 V, AC current range of 3-5 A, DC load capacity up to 125 VDC, DC input current range of 0.2-5 A, switching power up to 750 VA or 90W, a maximum switching frequency of
Question 3: What is the maximum AC and DC current range supported by the National Instruments cFP-RLY-425 Relay Output Module?
Answer 3: The National Instruments cFP-RLY-425 Relay Output Module, designed for Compact FieldPoint systems, possesses various electrical specifications and features, including eight non-latching, SPST, normally open relay channels, an AC input range up to 250 V, an AC current range of 3-5 A, a DC load capacity up to 125 VDC, a DC input current range of 0.2-5 A, a maximum switching power of 750 VA or 90W
Question 4: What are the various electrical specifications and features of the National Instruments cFP-RLY-425 Relay Output Module designed for Compact FieldPoint systems?
Answer 4: The National Instruments cFP-RLY-425 Relay Output Module for Compact FieldPoint systems is equipped with eight non-latching, SPST, normally open relay channels, an AC input range of up to 250 V, an AC current range of 3-5 A, a DC load capacity of up to 125 VDC, a DC input current range of 0.2-5 A, a switching power of up to 750 VA or 90 W, and it can operate
Question 5: What are the characteristics and specifications of the National Instruments cFP-RLY-425 Relay Output Module designed for Compact FieldPoint systems?
Answer 5: The National Instruments cFP-RLY-425 Relay Output Module can handle a maximum AC voltage of 250 V and an AC current range between 3-5 A for Compact FieldPoint systems.