Description
The National Instruments cFP-RTD-124 Temperature Input Module, with part number 777318-124, is a versatile device suitable for a range of applications such as process control, device testing, and temperature chamber control. It is designed to work with 2, 3, and 4-wire RTDs, as well as millivolt level voltages and thermocouples, offering flexibility in temperature sensing.
This 16-bit resolution module requires a power input of 350 mW and provides a direct resistance measurement range up to 400 Ω. Featuring a delta-sigma type Analog to Digital Conversion (ADC), it allows for software selectable input signal ranges and has a signal input bandwidth of 3 Hz.
Each channel on the cFP-RTD-124 is updated once per second, ensuring timely data for accurate monitoring. The module is relatively lightweight at 3.7 oz and has compact physical dimensions of 5.0 x 3.5 x 1.0 inches. It is built to operate within a robust temperature range, making it suitable for various industrial environments.
Specification | Detail |
---|---|
Part Number | 777318-124 |
Product Name | National Instruments cFP-RTD-124 Temperature Input Module |
Manufacturer | National Instruments |
Module Type | Temperature Input Module |
Compatibility | 2, 3, and 4-wire RTDs, millivolt level voltages, and thermocouples |
Applications | Process control, device testing, temperature chamber control |
Resolution | 16-bit |
Power Requirement | 350 mW |
Direct Resistance Measurement Range | 400 Ω |
Analog to Digital Conversion (ADC) | Delta-sigma type |
Input Signal Ranges | Software selectable |
Signal Input Bandwidth | 3 Hz |
Update Rate | Each channel updated once per second |
Weight | 3.7 oz |
Dimensions | 5.0 x 3.5 x 1.0 inches |
Question 1: What types of temperature sensors is the National Instruments cFP-RTD-124 Temperature Input Module compatible with, and what are its key specifications in terms of power input, resistance measurement range, and update frequency?
Answer 1: The National Instruments cFP-RTD-124 Temperature Input Module is designed to work with 2, 3, and 4-wire RTDs, and it has a signal input bandwidth of 3 Hz.
Question 2: What types of RTDs and signal levels is the National Instruments cFP-RTD-124 Temperature Input Module designed to work with, and what are its key specifications in terms of resolution, power requirement, resistance measurement range, and signal input bandwidth?
Answer 2: The National Instruments cFP-RTD-124 Temperature Input Module is a highly adaptable device characterized by its compatibility with 2, 3, and 4-wire RTDs, millivolt level voltages, and thermocouples, alongside a 16-bit resolution that enables precise temperature readings. With a power requirement of 350 mW, a direct resistance measurement range up to 400 Ω, and a delta-sigma type ADC with a 3 Hz signal input bandwidth, it
Question 3: What types of RTDs is the National Instruments cFP-RTD-124 Temperature Input Module designed to work with, and what are its key features in terms of power requirements, resolution, and physical specifications?
Answer 3: The National Instruments cFP-RTD-124 Temperature Input Module is designed to work with 2, 3, and 4-wire RTDs, as well as with millivolt level voltages and thermocouples, and features a 16-bit resolution, requires a power input of 350 mW, offers a direct resistance measurement range up to 400 Ω, and has a signal input bandwidth of 3 Hz.
Question 4: What types of RTDs is the National Instruments cFP-RTD-124 Temperature Input Module designed to work with, and what is its signal input bandwidth?
Answer 4: The National Instruments cFP-RTD-124 Temperature Input Module is designed to work with 2, 3, and 4-wire RTDs, as well as with millivolt level voltages and thermocouples; it has key features including a 16-bit resolution, a power requirement of 350 mW, and compact physical dimensions of 5.0 x 3.5 x 1.0 inches, with a weight of 3.7 oz.
Question 5: What are the key features and specifications of the National Instruments cFP-RTD-124 Temperature Input Module, and how do they contribute to its applicability in various temperature sensing applications?
Answer 5: The National Instruments cFP-RTD-124 Temperature Input Module is compatible with 2, 3, and 4-wire RTDs, millivolt level voltages, and thermocouples, and it has key specifications including a power input requirement of 350 mW, a direct resistance measurement range up to 400 Ω, and an update frequency of once per second for each channel.