The HP Agilent E4418B is a Power Meter. This model weighs 8.8 pounds and has dimensions of 8.5 x 3.5 x 13.7 inches.


Description

Item #: E4418B

Manufacturer: Agilent
Series: EPM

E4418B by Agilent is a Power Meter in the EPM series. E4418B features a Frequency range of 100 kHz to 110 GHz and a Power range of -70 dB to +44 dBm (100 pW to 25 W).

The HP Agilent E4418B Power Meter is ideal for bench and automatic test equipment (ATE) use. This Power Meter is compatible with all 8480 series and E-series sensors. The E4418B has a swift measurement speed, as fast as 200 readings per second over the GPIB, with the E-series sensors. There is a speed increase of two times with the 8480 series power sensor, when compared to the 437B. There are not any range-switching delays with the 8480 series, while the E-series has a single fast-range switch point. GPIB and RS-232 connectors are available with this power meter for remote control of every function.

If Option 1 is added for an internal rechargeable battery, the E4418B Power Meter will have an approximate operating time of 3.5 hours with the LED backlight on. The battery life can, however, be extended to 5.5 hours with the LED backlight off. The power meter needs a 30 minute warm-up before being used in order to reach the specifications stated in the user manual.

The frequency range is 9 kHz to 110 GHz, depending on the sensor. The power range is -70 dBm to +44 dBm (100 pW to 25W), depending on the sensor. There are three measurement speed modes over the GPIB. With the E4418B Power Meter, the normal measurement speed is 20 readings per second. The speed times two is 40 readings per second. The final measurement speed is fast, which equates to 200 readings per second. The fast mode is only for E-series sensors.

Specifications


Manufacturer Agilent
Part Number E4418B
Series EPM
Type Power Meter
Frequency range 100 kHz to 110 GHz
Power range -70 dB to +44 dBm (100 pW to 25 W)
Input frequency range 50 to 440 Hz
Interface GPIB
Dimensions 8.5 x 3.5 x 13.7 in.
Weight 8.8 lbs.
Option 1 Mains power and internal rechargeable battery
Option 2 Parallel rear panel sensor input connector(s) and front panel reference calibrator connector
Option 3 Parallel rear panel sensor input connectors and rear panel reference calibrator connector
Option A6J ANSI Z540 compliant calibration test data including measurement uncertainties
Option 1A7 ISO17025 compliant calibration test data including measurement uncertainties
Option 0B0 Delete hard copy English language User’s Guide
Option 0BF Hard copy English language Programming Guide
Option 915 Hard copy English language Service Manual
Option 916 Additional hard copy English language User’s Guide and Programming Guide
Option ABD Hard copy German localization User’s Guide and Programming Guide
Option ABE Hard copy Spanish localization User’s Guide and Programming Guide
Option ABF Hard copy French localization User’s Guide and Programming Guide
Option ABJ Hard copy Japanese localization User’s Guide and Programming Guide
Option 4 Delete power sensor cable from standard inclusion with power meter
Option 908 Rackmount kit (one instrument)
Option 909 Rackmount kit (two instruments)

Additional information

Manufacturer

Part Number

Series

Type

Frequency Range