img

FD-11614

The National Instruments FD-11614 Temperature Input Device, part number 785854-01, is a FieldDAQ family product with 16 thermocouple channels, NI-DAQmx driver compatibility, shock resistance up to 100 g, IP67

In Stock | Ships Today

img

    Description

    The FD-11614 Temperature Input Device, with part number 785854-01, is a robust product from National Instruments tailored for the FieldDAQ family. Compatible with NI-DAQmx drivers and designed to operate with Windows operating systems, this device is well-equipped to handle a variety of applications.

    Featuring 16 thermocouple channels, the FD-11614 is capable of withstanding a shock range of up to 100 g and can operate under a maximum vibration of 10 g. It includes cold junction compensation and has an advanced feature for open thermocouple detection, complete with an LED indicator for each channel to signal any disconnections.

    This device boasts an ingress protection rating of IP67, ensuring it is protected against dust and water immersion, making it suitable for harsh environmental conditions. It also incorporates time-sensitive networking facilities for efficient data handling. Designed to function in a wide operating temperature range from -40 degrees to 85 degrees C, the FD-11614 is ideal for outdoor environments and test cell applications. Lastly, it supports daisy chaining over built-in power circuits, simplifying the setup process for multiple device configurations.

    Feature Specification
    Part Number 785854-01
    Product Name FD-11614 Temperature Input Device
    Manufacturer National Instruments
    Device Family FieldDAQ
    Driver Compatibility NI-DAQmx
    Operating Systems Windows
    Number of Channels 16 thermocouple channels
    Shock Range 100 g
    Maximum Vibration 10 g
    Cold Junction Compensation Yes
    Open Thermocouple Detection Yes, with LED indicator for each channel
    Ingress Protection IP67
    Networking Time-sensitive networking facility
    Operating Temperature Range -40 degrees to 85 degrees C
    Applications Outdoor environments, test cells
    Daisy Chaining Capability Yes, over built-in power circuits

    Question 1: What advanced feature does the FD-11614 Temperature Input Device from National Instruments offer for detecting disconnections in its thermocouple channels?
    Answer 1: The operating temperature range for the FD-11614 Temperature Input Device from National Instruments is from -40 degrees to 85 degrees Celsius, and its IP67 rating benefits its performance in harsh environmental conditions by ensuring it is dust-tight and protected against the effects of temporary immersion in water, making it suitable for outdoor or industrial settings where it might be exposed to such elements.

    Question 2: What is the operating temperature range for the FD-11614 Temperature Input Device from National Instruments, and how does its IP67 rating benefit its performance in harsh environmental conditions?
    Answer 2: The FD-11614 Temperature Input Device from National Instruments is exceptionally durable and suitable for demanding outdoor environments and test cell applications due to its ability to withstand a shock range of up to 100 g, operate under a maximum vibration of 10 g, and function in a wide operating temperature range from -40 degrees to 85 degrees Celsius, paired with its ingress protection rating of IP67 which ensures protection against dust and water immersion.

    Question 3: What are the main features and compatibility specifications of the FD-11614 Temperature Input Device from National Instruments?
    Answer 3: The FD-11614 Temperature Input Device from National Instruments is suitable for harsh environmental conditions and complex data handling applications due to its robust ingress protection rating of IP67, which guards against dust and water immersion, its ability to withstand significant shock and vibration, and its advanced features such as cold junction compensation, open thermocouple detection with LED indicators, and time-sensitive networking facilities, along with the support for a wide operating temperature range from -40 degrees to 85 degrees C, making it ideal for challenging

    Question 4: What capabilities and features make the FD-11614 Temperature Input Device from National Instruments a suitable choice for harsh environmental conditions and complex data handling applications?
    Answer 4: The FD-11614 Temperature Input Device from National Instruments offers an advanced feature for open thermocouple detection, which is accompanied by an LED indicator for each channel to signal any disconnections.

    Question 5: What features make the FD-11614 Temperature Input Device from National Instruments exceptionally durable and suitable for demanding outdoor environments and test cell applications?
    Answer 5: The FD-11614 Temperature Input Device from National Instruments features 16 thermocouple channels, is compatible with NI-DAQmx drivers, and operates on Windows operating systems. It can withstand up to 100 g of shock, operate under a maximum vibration of 10 g, and offers cold junction compensation and open thermocouple detection with LED indicators for each channel. The device is IP67 rated for protection against dust and water immersion, supports time-sensitive networking, functions in temperatures ranging from -40