img

FD-11634

The FD-11634 is a rugged, water-resistant, and dustproof Sound and Vibration Input Device for FieldDAQ with a 24-bit resolution, 102.4 kS/s sampling rate, software-selectable AC/DC input coupling,

In Stock | Ships Today

img

    Description

    The FD-11634 (Part Number: 786471-01) is a robust Sound and Vibration Input Device tailored for FieldDAQ systems, designed to work with microphones and accelerometers to deliver accurate measurements. It features a 24-bit input resolution and a high sampling rate of 102.4 kS/s for each of its 8 analog input channels, ensuring precise data collection.

    It accommodates a versatile range of input voltage levels, including ±10 V and ±1 V, which can be selected through software-controlled AC/DC input coupling. The device is supported by the NI-DAQ driver provided by National Instruments and is compatible with power supplies PS-15 (Part Number: 147464-01) and PS-16 (Part Number: 781094-01).

    Constructed to withstand challenging environments, the FD-11634 is both water-resistant and dustproof, enhancing its suitability for industrial and field applications. It also incorporates an internal IEPE signal conditioning accessory and a brickwall filter to further refine measurement quality. The device supports advanced networking with TSN, TCP/IP, and UDP protocols, and is engineered with an input capacitance of 520 pF, contributing to its high-performance specifications.

    Question 1: What features contribute to the precise data collection capabilities of the FD-11634 Sound and Vibration Input Device, and how does it ensure compatibility and durability for industrial and field applications?
    Answer 1: The FD-11634 Sound and Vibration Input Device for FieldDAQ systems boasts a 24-bit input resolution and a high sampling rate of 102.4 kS/s across 8 analog input channels, supports input voltage levels of ±10 V and ±1 V via software-controlled AC/DC input coupling, and is compatible with National Instruments’ NI-DAQ driver and power supplies PS-15 and PS-16. It is also water-resistant, dustproof, features internal IEPE signal conditioning

    Question 2: What power supplies are compatible with the FD-11634 Sound and Vibration Input Device, and how do they enhance its capacity for precise data collection in industrial and field environments?
    Answer 2: The FD-11634 Sound and Vibration Input Device offers precise data collection through its 24-bit input resolution and high sampling rate of 102.4 kS/s across 8 analog input channels, and it ensures compatibility and durability for industrial and field applications with its software-selectable input voltage levels, support for National Instruments’ NI-DAQ driver, water-resistant and dustproof construction, internal IEPE signal conditioning, brickwall filter, and advanced networking capabilities with TSN, TCP/IP, and

    Question 3: What type of environments is the FD-11634 Sound and Vibration Input Device designed to endure, considering its water-resistant and dustproof construction?
    Answer 3: The FD-11634 Sound and Vibration Input Device is designed to endure challenging industrial and field environments, thanks to its water-resistant and dustproof construction.

    Question 4: What are the characteristics and compatibility features of the FD-11634 Sound and Vibration Input Device designed for FieldDAQ systems?
    Answer 4: The FD-11634 Sound and Vibration Input Device is compatible with the PS-15 (Part Number: 147464-01) and PS-16 (Part Number: 781094-01) power supplies, which support its functionality in industrial and field environments by ensuring a stable power source, thereby contributing to the device’s ability to consistently deliver accurate measurements.

    Question 5: What are the key features and specifications of the FD-11634 Sound and Vibration Input Device for FieldDAQ systems?
    Answer 5: The FD-11634 is a Sound and Vibration Input Device for FieldDAQ systems with key features that include 24-bit input resolution, a high sampling rate of 102.4 kS/s across 8 analog input channels, software-selectable input voltage levels of ±10 V and ±1 V, compatibility with National Instruments’ NI-DAQ driver, and support for power supplies PS-15 and PS-16. It is water-resistant, dustproof, includes IEPE signal conditioning, a

    Specification Detail
    Part Number FD-11634 (786471-01)
    Product Type Sound and Vibration Input Device for FieldDAQ
    Input Voltage Ranges ±10 V, ±1 V
    Driver Support NI-DAQ driver by National Instruments
    Compatible Power Supplies PS-15 (147464-01), PS-16 (781094-01)
    Application Designed for microphones and accelerometers
    Input Resolution 24-bit
    Sampling Rate 102.4 kS/s per channel
    IEPE Signal Conditioning Internal accessory
    Number of Analog Input Channels 8
    Input Coupling AC/DC, software-selectable
    Ruggedness Water-resistant and dustproof
    Networking TSN, TCP/IP, UDP
    Input Capacitance 520 pF
    Filter Type Brickwall filter