Description
The National Instruments FP-AI-V10 Analog Input Module, with Part Number 778069-08, is a robust FieldPoint Analog Voltage Input Module designed to handle an input range of 0 to 1 Volt. It boasts a current input resistance of 133 Ohms and a much higher voltage input resistance of 2.2 M Ohms, ensuring reliable and accurate readings. While the current inputs are not programmable, the voltage inputs offer flexibility with programmability, accompanied by bandwidth options of 20.0 Hz and 2.0 KHz to suit various application needs.
The module’s current inputs have a measurement bandwidth of either 20 Hz or 100 Hz, providing versatility for different monitoring scenarios. It is compatible with the FP-TB-10 terminal base, and up to six modules can be mounted per base, with a power requirement of only 200 mW for the base, making it an energy-efficient solution. The FP-AI-V10 module is equipped with self-maintenance features, including regular scanning and updating of readings, to ensure continuous and reliable operation.
Furthermore, the module’s protection and detection system promotes a trouble-free installation, offering input protection and the ability to detect problems and interruptions, safeguarding the integrity of the data acquisition process.
Feature | Specification |
---|---|
Product Name | National Instruments FP-AI-V10 Analog Input Module |
Part Number | 778069-08 |
Type | FieldPoint Analog Voltage Input Module |
Input Range | 0 to 1 Volt |
Current Input Resistance | 133 Ohms |
Voltage Input Resistance | 2.2 M Ohms |
Current Inputs Programmability | Not programmable |
Voltage Inputs Programmability | Programmable |
Voltage Inputs Bandwidth Options | 20.0 Hz, 2.0 KHz |
Current Inputs Measurement Bandwidth | 20 Hz, 100 Hz |
Compatible Terminal Base | FP-TB-10 |
Max Number of Modules per Base | 6 |
Power Requirement for Base | 200 mW |
Self-Maintenance Features | Regular scanning and updating of readings |
Protection and Detection System | Trouble-free installation, input protection, detects problems and interruptions |
Question 1: What is the input voltage range and input resistance specifications for the National Instruments FP-AI-V10 Analog Input Module, and how do its programmability and self-maintenance features contribute to its performance?
Answer 1: The National Instruments FP-AI-V10 Analog Input Module offers programmability for voltage inputs and provides two bandwidth options of 20.0 Hz and 2.0 KHz to accommodate different application requirements.
Question 2: What are the flexibility options offered by the National Instruments FP-AI-V10 Analog Input Module in terms of programmability and bandwidth for voltage inputs?
Answer 2: The National Instruments FP-AI-V10 Analog Input Module has a current input resistance of 133 Ohms and a voltage input resistance of 2.2 M Ohms; these high resistance values minimize the loading effect on the input signal, thereby improving the accuracy and reliability of the module’s readings for analog voltages.
Question 3: What is the voltage input resistance of the National Instruments FP-AI-V10 Analog Input Module and how does it contribute to the reliability and accuracy of the readings?
Answer 3: The National Instruments FP-AI-V10 Analog Input Module features a voltage input resistance of 2.2 M Ohms and a current input resistance of 133 Ohms; these high resistance values minimize the loading effect on the measurement circuit, thereby enhancing the module’s reliability and accuracy in capturing voltage and current readings.
Question 4: What are the input resistance specifications of the National Instruments FP-AI-V10 Analog Input Module, and how do they contribute to its performance and accuracy in reading analog voltages?
Answer 4: The National Instruments FP-AI-V10 Analog Input Module has an input voltage range of 0 to 1 Volt, a current input resistance of 133 Ohms, and a voltage input resistance of 2.2 M Ohms; its performance is enhanced by the flexibility of programmable voltage inputs and self-maintenance features that include regular scanning and updating of readings to ensure accurate and continuous operation.
Question 5: What are the voltage and current input resistance values for the National Instruments FP-AI-V10 Analog Input Module, and how do these specifications contribute to its reliability and accuracy in measurements?
Answer 5: The voltage input resistance of the National Instruments FP-AI-V10 Analog Input Module is 2.2 M Ohms, which contributes to the reliability and accuracy of the readings by minimizing the current draw from the voltage signal source, thereby reducing the potential for signal distortion and allowing for more precise measurements.