The National Instruments FP-CTR-500 is an 8-channel counter module with a part number 777518-500, accepting 10 to 30 VDC input voltage, capable of handling up to 50 kHz input frequency and provides options for

In Stock | Ships Today

img

    Description

    The National Instruments FP-CTR-500 Counter Module, with Part Number 777518-500, is a versatile 8-channel counter module designed for a wide range of industrial applications.

    It supports an input voltage range from 10 to 30 VDC and is capable of handling maximum input frequencies up to 50 kHz. The counter width can be expanded up to 128 bits through channel cascading, allowing for extensive count ranges.

    Users can measure frequency using either internal or external gate inputs, and the module provides configurable low-pass filters to manage signal noise effectively.

    The input channels are optically isolated and feature current-limiting circuitry for enhanced protection. With eight count-input channels and four gate-input channels, the module is well-suited for complex counting tasks.

    Output configuration options include the ability to set counter outputs to pulse or toggle states, which is especially useful for automating processes. The VSUP and COM terminals offer power supply options for field instruments, and the module’s VIN terminal serves as a sinking input, ensuring compatibility with a variety of signal sources.

    Attribute Description
    Manufacturer National Instruments
    Product Name FP-CTR-500 Counter Module
    Part Number 777518-500
    Channels 8-Channel Counter Module
    Input Voltage Range 10 to 30 VDC
    Maximum Input Frequency 50 kHz
    Counter Width Up to 128 bits (cascadable)
    Frequency Measurement Internal or External Gate Inputs
    Low-Pass Filters Configurable
    Input Channels Optically Isolated with Current-limiting Circuitry
    Count-Input Channels 8
    Gate-Input Channels 4
    Output Configuration Pulse or Toggle on Counter Outputs
    Power Supply to Field Instruments VSUP and COM Terminals
    Input Terminal VIN
    Input Type Sinking

    Question 1: What are the key features of the National Instruments FP-CTR-500 Counter Module, and how do they contribute to its suitability for complex industrial counting tasks?
    Answer 1: The National Instruments FP-CTR-500 Counter Module manages noise in signal input by offering configurable low-pass filters, and it ensures enhanced protection for its input channels through optical isolation and current-limiting circuitry.

    Question 2: What are the capabilities and features of the National Instruments FP-CTR-500 Counter Module, including its part number, voltage range, maximum input frequency, counter width, and input options?
    Answer 2: The National Instruments FP-CTR-500 Counter Module, with Part Number 777518-500, offers capabilities such as an 8-channel counter with an input voltage range of 10 to 30 VDC and a maximum input frequency of 50 kHz. Its counter width can be expanded up to 128 bits through channel cascading, and it supports frequency measurement using internal or external gate inputs. Additionally, the module features optically isolated input channels with current-limiting circuitry, configurable low-pass

    Question 3: What are the key features and capabilities of the National Instruments FP-CTR-500 Counter Module, including its input voltage range, input frequency, counter width, and input/output configurations?
    Answer 3: The National Instruments FP-CTR-500 Counter Module is an 8-channel counter capable of supporting a 10 to 30 VDC input voltage range, handling maximum input frequencies up to 50 kHz, and offering a counter width that can be expanded up to 128 bits through channel cascading. It allows frequency measurement using internal or external gate inputs and offers output configuration options that include setting counter outputs to pulse or toggle states, providing versatility for various industrial applications.

    Question 4: How does the National Instruments FP-CTR-500 Counter Module handle noise in signal input, and what features ensure enhanced protection for its input channels?
    Answer 4: The key features of the National Instruments FP-CTR-500 Counter Module include its 8-channel configuration, support for 10 to 30 VDC input voltage, maximum input frequencies up to 50 kHz, expandable counter width up to 128 bits through channel cascading, and the ability to measure frequency with internal or external gate inputs. Additionally, it offers configurable low-pass filters for noise management, optically isolated input channels with current-limiting circuitry for protection, and four gate-input channels

    Question 5: What are the capabilities and features of the National Instruments FP-CTR-500 Counter Module, particularly in terms of voltage range, input frequency, counter width, and options for measuring frequency and output configuration?
    Answer 5: The National Instruments FP-CTR-500 Counter Module boasts key features including an input voltage range of 10 to 30 VDC, handling of input frequencies up to 50 kHz, an expandable counter width of up to 128 bits through channel cascading, optically isolated input channels with current-limiting circuitry, eight count-input and four gate-input channels, configurable low-pass filters, and output configurations that allow for pulse or toggle states, all designed to support complex industrial counting applications.