Description
The PXI ARINC 429 Interface Module, part number LV-222-442-442, and National Instruments part number 784804-01, is a product of Astronics Ballard Technology/National Instruments. This high-performance module features 32 bidirectional channels and utilizes a PCIe x1 interface architecture for seamless connectivity.
Designed for compatibility with the OmniBus II product line, this interface module can flexibly operate with either one or two 16-channel modules loaded, catering to various user needs.
Among its robust features are programmable frequency and variable transmit amplitude, as well as the capability to support the transmission of both periodic and asynchronous messages using the widely adopted ARINC 429 avionics databus protocol.
Ensuring reliability and functionality, the module is equipped with internal test functions and sophisticated hardware test circuitries for monitoring the module’s health. Furthermore, it boasts advanced 64-bit time-tagging capabilities with an impressive 1 nanosecond resolution, enabling precise synchronization and timestamping of data.
Attribute | Details |
---|---|
Manufacturer | Astronics Ballard Technology/National Instruments |
Part Number | LV-222-442-442 |
National Instruments Part Number | 784804-01 |
Product Type | PXI ARINC 429 Interface Module |
Number of Channels | 32 bidirectional channels |
Interface Architecture | PCIe x1 |
Compatibility | OmniBus II product line |
Operating Modes | Can operate with one or two 16-channel modules loaded |
Features | Programmable frequency, variable transmit amplitude, supports transmission of periodic and asynchronous messages |
Avionics Databus Protocol | ARINC 429 |
Test Functions | Internal test functions with hardware test circuitries |
Time-Tagging | 64-bit time-tags with 1 nanosecond resolution |
Question 1: What are the capabilities and interface architecture of the PXI ARINC 429 Interface Module, part number LV-222-442-442?
Answer 1: The PXI ARINC 429 Interface Module, part number LV-222-442-442, boasts key features such as 32 bidirectional channels, PCIe x1 interface architecture, programmable frequency, variable transmit amplitude, and the ability to handle periodic and asynchronous messages in line with the ARINC 429 protocol; it is compatible with the OmniBus II product line and can operate with one or two 16-channel modules, also offering advanced functionalities like internal test functions, hardware test circuitries,
Question 2: What are the features and capabilities of the PXI ARINC 429 Interface Module, and how does it integrate with the OmniBus II product line?
Answer 2: The PXI ARINC 429 Interface Module, part number LV-222-442-442, features 32 bidirectional channels, a PCIe x1 interface architecture, programmable frequency, variable transmit amplitude, and the ability to transmit both periodic and asynchronous messages using the ARINC 429 protocol, along with advanced 64-bit time-tagging with 1 nanosecond resolution.
Question 3: What are the capabilities and compatibility features of the PXI ARINC 429 Interface Module part number LV-222-442-442, and how do its advanced functions ensure precise data synchronization and module health monitoring?
Answer 3: The PXI ARINC 429 Interface Module, part number LV-222-442-442, is capable of bidirectional communication across 32 channels, and is compatible with the OmniBus II product line, offering flexibility with support for either one or two 16-channel modules. Its advanced functions include programmable frequency, variable transmit amplitude, and the ability to handle both periodic and asynchronous messages using the ARINC 429 protocol. For precise data synchronization, it features 64-bit time-tagging with
Question 4: What are the key features and compatibilities of the PXI ARINC 429 Interface Module, part number LV-222-442-442?
Answer 4: The PXI ARINC 429 Interface Module, part number LV-222-442-442, boasts 32 bidirectional channels, PCIe x1 interface architecture, programmable frequency, variable transmit amplitude, and the ability to handle both periodic and asynchronous messages following the ARINC 429 protocol. It integrates with the OmniBus II product line by allowing the flexibility to operate with one or two 16-channel modules and includes internal test functions, hardware test circuitries for health monitoring, and advanced 64
Question 5: What are the specifications and features of the PXI ARINC 429 Interface Module, part number LV-222-442-442, including its channel capacity, interface type, and compatibility with other product lines?
Answer 5: The PXI ARINC 429 Interface Module, part number LV-222-442-442, features 32 bidirectional channels, a PCIe x1 interface architecture for connectivity, and is designed to be compatible with the OmniBus II product line; it also includes programmable frequency, variable transmit amplitude, support for periodic and asynchronous messages in the ARINC 429 protocol, internal test functions, hardware test circuitries, and advanced 64-bit time-tagging with 1 nanosecond resolution.