Description
The National Instruments LV-222-511-000, with a part number of 784797-01 and designed by Astronics/Ballard Technology, is a versatile PXI MIL-STD-1553 Interface Module that comes as a 2-channel unit but can be expanded to a 4-channel setup with the addition of extra modules. It offers three levels of functionality including Remote Terminal (RT), Bus Monitor Operation, and Bus Control to cater to a wide range of applications.
Among its advanced features are protocol error injection and the ability to simulate multiple terminals, supporting up to 32 terminals. This is complemented by a selectable Clock Switch that allows users to choose between using the PXI connector’s clock input or an internal 100 MHz oscillator for protocol timing.
Software-adjustable RT response times offer further flexibility, while the module’s discrete outputs are capable of sinking currents up to 200 mA and can tolerate voltages up to 35 VDC. Moreover, the module provides 16 1553 discrete I/O ports, which can be configured to serve as general-purpose digital I/O, adding to the module’s utility.
Attribute | Details |
---|---|
Manufacturer | National Instruments, designed by Astronics/Ballard Technology |
Part Number | LV-222-511-000 (National Instruments Part Number: 784797-01) |
Type | PXI MIL-STD-1553 Interface Module |
Channels | 2-Channel, expandable to 4-channel with additional modules |
Functionality Levels | Remote Terminal (RT), Bus Monitor Operation, Bus Control |
Features | Protocol error injection, multi-terminal simulation (up to 32 terminals), selectable Clock Switch |
Clock Input Options | PXI connector’s clock input or internal 100 MHz oscillator |
RT Response Time | Individually adjustable in software |
Discrete Outputs Current Capacity | Up to 200 mA |
Discrete Outputs Voltage Tolerance | Up to 35 VDC |
1553 Discrete I/O | 16, configurable as general-purpose digital I/O |
Question 1: What advanced features does the National Instruments LV-222-511-000, a PXI MIL-STD-1553 Interface Module designed by Astronics/Ballard Technology, offer to support multiple terminals and provide timing for protocols?
Answer 1: The advanced feature of the National Instruments LV-222-511-000 Interface Module that supports the simulation of up to 32 terminals and includes the use of a selectable Clock Switch with an internal 100 MHz oscillator is its capability for protocol error injection.
Question 2: What are the primary functions and advanced features of the National Instruments LV-222-511-000 PXI MIL-STD-1553 Interface Module designed by Astronics/Ballard Technology, and how does it support customization for different applications?
Answer 2: The National Instruments LV-222-511-000 MIL-STD-1553 Interface Module, designed by Astronics/Ballard Technology and bearing part number 784797-01, is a versatile 2-channel PXI unit expandable to 4 channels, offering Remote Terminal, Bus Monitor Operation, and Bus Control functionalities; it includes advanced features such as protocol error injection, the ability to simulate up to 32 terminals, a selectable clock switch for timing protocol with an internal 100 MHz
Question 3: What advanced feature of the National Instruments LV-222-511-000 Interface Module supports simulation of up to 32 terminals and includes the use of a selectable Clock Switch with an internal 100 MHz oscillator?
Answer 3: The National Instruments LV-222-511-000 offers advanced features such as protocol error injection and the ability to simulate up to 32 terminals, along with a selectable Clock Switch that enables users to choose between the PXI connector’s clock input or an internal 100 MHz oscillator to ensure precise protocol timing.
Question 4: What are the key features and capabilities of the National Instruments LV-222-511-000 PXI MIL-STD-1553 Interface Module designed by Astronics/Ballard Technology?
Answer 4: The National Instruments LV-222-511-000 PXI MIL-STD-1553 Interface Module, designed by Astronics/Ballard Technology, serves primary functions such as Remote Terminal operation, Bus Monitoring, and Bus Control, and offers advanced features like protocol error injection, the simulation of up to 32 terminals, and a selectable Clock Switch for timing precision with either an external PXI connector clock or an internal 100 MHz oscillator. It supports customization through its expandability from 2 to
Question 5: What are the key features and capabilities of the Astronics/Ballard Technology-designed National Instruments LV-222-511-000 MIL-STD-1553 Interface Module, with part number 784797-01?
Answer 5: The National Instruments LV-222-511-000, a PXI MIL-STD-1553 Interface Module designed by Astronics/Ballard Technology, offers key features such as a 2-channel configuration expandable to 4 channels, support for Remote Terminal, Bus Monitor Operation, and Bus Control functions, the ability to simulate up to 32 terminals, protocol error injection, a selectable Clock Switch for timing with an internal 100 MHz oscillator or PXI connector’s clock input, software-adjust