img

NI-5761

The National Instruments NI-5761 Digitizer Adapter Module for FlexRIO offers a 250 MS/s sampling rate, 500 MHz bandwidth, 14-bit resolution, and four simultaneously sampled channels, along with versatile connectivity including AC and DC-cou

In Stock | Ships Today

img

    Description

    The National Instruments NI-5761 Digitizer Adapter Module for FlexRIO is a high-performance device capable of a 250 MS/s sampling rate and a 500 MHz bandwidth, suitable for demanding applications that require 14-bit resolution. It features four simultaneously sampled channels and eight general purpose digital I/O channels, ensuring versatility in various use cases.

    Available in both AC-coupled (Part Number: 781287-01) and DC-coupled (Part Number: 781287-02) configurations, this module accommodates a range of signal types. The front panel hosts an array of connectors including AUX I/O, four configurable LEDs, CLK IN, TRIG, and four analog input channels (CH 0 to CH 4), providing a user-friendly interface for setup and operation.

    Incorporating a component-level IP (CLIP), the NI-5761 module seamlessly integrates with LabVIEW software, simplifying development and deployment. The module’s integrated 250 MHz fixed frequency synthesizer type sample clock ensures precise timing, complemented by a 10 MHz reference clock for synchronization.

    For systems requiring customization, it supports an external sample clock through the CLK IN connector or IoModSyncClock, with the CLK IN featuring an SMA, 50 Ω AC input coupling. Additionally, an external trigger connector with SMA, DC input coupling is provided, enabling the module to interface with a variety of external triggering mechanisms.

    Feature Specification
    Product National Instruments NI-5761 Digitizer Adapter Module for FlexRIO
    Sampling Rate 250 MS/s
    Bandwidth 500 MHz
    Resolution 14-Bit
    Channels 4 simultaneously sampled channels
    Digital I/O Channels 8 general purpose
    AC-Coupled Configuration Part Number 781287-01
    DC-Coupled Configuration Part Number 781287-02
    Front Panel Connectors AUX I/O, 4 LEDs, CLK IN, TRIG, 4 Analog Input Channels (CH 0 to CH 4)
    Component-Level IP (CLIP) Yes
    Sample Clock Integrated 250 MHz fixed frequency synthesizer type
    Reference Clock 10 MHz
    External Sample Clock Input Yes, through CLK IN connector or IoModSyncClock
    CLK IN Connector SMA, 50 Ω AC input coupling
    External Trigger Connector SMA, DC input coupling

    Question 1: What are the distinguishing features and specifications of the National Instruments NI-5761 Digitizer Adapter Module for FlexRIO that make it suitable for high-performance applications?
    Answer 1: The National Instruments NI-5761 Digitizer Adapter Module for FlexRIO is suitable for high-performance applications due to its 250 MS/s sampling rate, 500 MHz bandwidth, 14-bit resolution, four simultaneously sampled channels, eight general-purpose digital I/O channels, both AC-coupled and DC-coupled configurations, front panel connectors for easy interfacing, and integration with LabVIEW software, as well as its 250 MHz fixed frequency synthesizer type sample clock, 10 MHz reference

    Question 2: What capabilities make the National Instruments NI-5761 Digitizer Adapter Module for FlexRIO suitable for demanding applications, and how does it ensure precise timing and synchronization?
    Answer 2: The National Instruments NI-5761 Digitizer Adapter Module for FlexRIO offers an external sample clock through the CLK IN connector or IoModSyncClock, featuring an SMA, 50 Ω AC input coupling, and an external trigger connector with SMA, DC input coupling, for synchronization and interfacing with various triggering mechanisms.

    Question 3: What kind of external connections does the National Instruments NI-5761 Digitizer Adapter Module for FlexRIO offer for synchronization and interfacing with various triggering mechanisms?
    Answer 3: The National Instruments NI-5761 Digitizer Adapter Module for FlexRIO is suitable for high-performance applications requiring simultaneous sampling and high-speed signal processing due to its 250 MS/s sampling rate, 500 MHz bandwidth, 14-bit resolution, four simultaneously sampled channels, eight general-purpose digital I/O channels, and integration with LabVIEW software, all of which are complemented by its component-level IP, 250 MHz fixed frequency synthesizer sample clock, and 10 MHz reference clock for precise timing

    Question 4: What are the key features and specifications of the National Instruments NI-5761 Digitizer Adapter Module for FlexRIO, including sampling rate, bandwidth, and resolution, and how do they contribute to its suitability for demanding applications?
    Answer 4: The National Instruments NI-5761 Digitizer Adapter Module for FlexRIO is suitable for demanding applications due to its high-performance features such as a 250 MS/s sampling rate, 500 MHz bandwidth, 14-bit resolution, and four simultaneously sampled channels; it ensures precise timing and synchronization with an integrated 250 MHz fixed frequency synthesizer type sample clock, complemented by a 10 MHz reference clock, and it also supports an external sample clock and external triggering mechanisms for additional customization and precision.

    Question 5: What are the specifications and features that make the National Instruments NI-5761 Digitizer Adapter Module for FlexRIO suitable for high-performance applications requiring simultaneous sampling and high-speed signal processing?
    Answer 5: The National Instruments NI-5761 Digitizer Adapter Module for FlexRIO boasts key features such as a 250 MS/s sampling rate, 500 MHz bandwidth, and 14-bit resolution, along with four simultaneously sampled channels and eight general-purpose digital I/O channels, which together provide the high-speed data acquisition and precise signal fidelity required for complex and demanding applications.