Description
The National Instruments PCI-4461 Sound and Vibration Device, part number 779307-01, is designed to deliver high-precision data acquisition for sound and vibration analysis with its integrated 2-channel dynamic signal generation and acquisition.
Featuring AC/DC configurable coupling and integrated IEPE conditioning, this device is well-equipped for precise measurements with various transducers. The 24-bit resolution ADCs provide clear and accurate data capture, and users can choose from multiple sampling rates, including 44.1 kS/s, 48.0 kS/s, 96.0 kS/s, and 192 kS/s, to match the requirements of standard audio applications.
The delta-sigma ADC type and an input gain range of -20 to +30 dB in 10 dB steps ensure flexibility in signal processing, while the impressive 118 dB dynamic range and frequency range from DC to 92 kHz allow for capturing a wide spectrum of sounds. With a typical Total Harmonic Distortion (THD) of -107 dB, the PCI-4461 ensures high-fidelity recordings.
Moreover, the device accommodates both analog and digital triggers, enhancing its versatility in various testing scenarios. It is also relatively lightweight at 8.5 oz and compact with dimensions of 6.3 x 3.9 inches, making it an easy fit for most work environments.
Question 1: What are the benefits of using the National Instruments PCI-4461 Sound and Vibration Device for sound and vibration analysis in terms of its data capture resolution and range of sampling rates?
Answer 1: The National Instruments PCI-4461 Sound and Vibration Device offers the benefits of high-precision data capture through its 24-bit resolution ADCs, ensuring clear and accurate data, and a range of sampling rates including 44.1 kS/s, 48.0 kS/s, 96.0 kS/s, and 192 kS/s, which allows users to select the optimal rate to match the requirements of various standard audio and vibration analysis applications.
Question 2: What are the features and specifications of the National Instruments PCI-4461 Sound and Vibration Device that make it suitable for precise sound and vibration analysis?
Answer 2: The National Instruments PCI-4461 Sound and Vibration Device is suitable for high-precision sound and vibration analysis due to its 24-bit resolution ADCs, selectable sampling rates up to 192 kS/s, integrated IEPE conditioning, a dynamic range of 118 dB, a frequency range up to 92 kHz, an input gain range of -20 to +30 dB, and a low Total Harmonic Distortion of -107 dB, along with support for both analog and digital triggers.
Question 3: What features make the National Instruments PCI-4461 Sound and Vibration Device suitable for high-precision sound and vibration analysis?
Answer 3: The National Instruments PCI-4461 Sound and Vibration Device offers high-precision data acquisition with a 2-channel dynamic signal generator and acquisition system, featuring AC/DC configurable coupling, integrated IEPE conditioning, 24-bit resolution ADCs, multiple sampling rates up to 192 kS/s, a delta-sigma ADC type with an input gain range of -20 to +30 dB, an impressive 118 dB dynamic range, a frequency range from DC to 92 kHz, and a low
Question 4: What are the key specifications of the National Instruments PCI-4461 Sound and Vibration Device that make it suitable for high-precision sound and vibration analysis?
Answer 4: The National Instruments PCI-4461 Sound and Vibration Device is suitable for high-precision sound and vibration analysis due to its integrated 2-channel dynamic signal generation and acquisition, AC/DC configurable coupling, integrated IEPE conditioning, 24-bit resolution ADCs with multiple sampling rates up to 192 kS/s, an input gain range of -20 to +30 dB, a 118 dB dynamic range, a frequency range from DC to 92 kHz, and a typical Total Harmonic Dist
Question 5: What features make the National Instruments PCI-4461 Sound and Vibration Device suitable for high-precision data acquisition in sound and vibration analysis?
Answer 5: The National Instruments PCI-4461 Sound and Vibration Device is suitable for high-precision data acquisition in sound and vibration analysis due to its two-channel dynamic signal generation and acquisition, AC/DC configurable coupling, integrated IEPE conditioning, 24-bit resolution ADCs with multiple sampling rates up to 192 kS/s, a delta-sigma ADC type with an input gain range of -20 to +30 dB, a dynamic range of 118 dB, a frequency range up to 92 kHz
Specification | Details |
---|---|
Product Name | National Instruments PCI-4461 Sound and Vibration Device |
Part Number | 779307-01 |
Channels | 2-channel dynamic signal generation, 2-channel dynamic signal acquisition |
Coupling | AC/DC configurable |
IEPE Conditioning | Integrated |
Resolution | 24-bit ADCs |
Sampling Rates | 44.1 kS/s, 48.0 kS/s, 96.0 kS/s, 192 kS/s |
ADC Type | Delta-sigma |
Input Gain Range | -20 to +30 dB in 10 dB steps |
Dynamic Range | 118 dB |
Frequency Range | DC to 92 kHz |
THD (Total Harmonic Distortion) | -107 dB typical |
Trigger Type | Analog and Digital |
Weight | 8.5 oz |
Dimensions | 6.3 x 3.9 in |