The National Instruments PCI-4461 is a sound and vibration device that offers 24-bit resolution across two dynamic signal generation and acquisition channels, with a dynamic range of 118 dB and a frequency range of DC to 92 kHz, suitable for various
The National Instruments PCI-4461 Sound and Vibration Device, part number 779307-01, is designed to deliver high-precision data acquisition for sound and vibration analysis with its integrated 2-channel dynamic signal generation and acquisition.
Featuring AC/DC configurable coupling and integrated IEPE conditioning, this device is well-equipped for precise measurements with various transducers. The 24-bit resolution ADCs provide clear and accurate data capture, and users can choose from multiple sampling rates, including 44.1 kS/s, 48.0 kS/s, 96.0 kS/s, and 192 kS/s, to match the requirements of standard audio applications.
The delta-sigma ADC type and an input gain range of -20 to +30 dB in 10 dB steps ensure flexibility in signal processing, while the impressive 118 dB dynamic range and frequency range from DC to 92 kHz allow for capturing a wide spectrum of sounds. With a typical Total Harmonic Distortion (THD) of -107 dB, the PCI-4461 ensures high-fidelity recordings.
Moreover, the device accommodates both analog and digital triggers, enhancing its versatility in various testing scenarios. It is also relatively lightweight at 8.5 oz and compact with dimensions of 6.3 x 3.9 inches, making it an easy fit for most work environments.
Specification
Details
Product Name
National Instruments PCI-4461 Sound and Vibration Device
Part Number
779307-01
Channels
2-channel dynamic signal generation, 2-channel dynamic signal acquisition
Coupling
AC/DC configurable
IEPE Conditioning
Integrated
Resolution
24-bit ADCs
Sampling Rates
44.1 kS/s, 48.0 kS/s, 96.0 kS/s, 192 kS/s
ADC Type
Delta-sigma
Input Gain Range
-20 to +30 dB in 10 dB steps
Dynamic Range
118 dB
Frequency Range
DC to 92 kHz
THD (Total Harmonic Distortion)
-107 dB typical
Trigger Type
Analog and Digital
Weight
8.5 oz
Dimensions
6.3 x 3.9 in
Question 1: What are the benefits of using the National Instruments PCI-4461 Sound and Vibration Device for sound and vibration analysis in terms of its data capture resolution and range of sampling rates? Answer 1: The National Instruments PCI-4461 Sound and Vibration Device offers the benefits of high-precision data capture through its 24-bit resolution ADCs, ensuring clear and accurate data, and a range of sampling rates including 44.1 kS/s, 48.0 kS/s, 96.0 kS/s, and 192 kS/s, which allows users to select the optimal rate to match the requirements of various standard audio and vibration analysis applications.
Question 2: What are the features and specifications of the National Instruments PCI-4461 Sound and Vibration Device that make it suitable for precise sound and vibration analysis? Answer 2: The National Instruments PCI-4461 Sound and Vibration Device is suitable for high-precision sound and vibration analysis due to its 24-bit resolution ADCs, selectable sampling rates up to 192 kS/s, integrated IEPE conditioning, a dynamic range of 118 dB, a frequency range up to 92 kHz, an input gain range of -20 to +30 dB, and a low Total Harmonic Distortion of -107 dB, along with support for both analog and digital triggers.
Question 3: What features make the National Instruments PCI-4461 Sound and Vibration Device suitable for high-precision sound and vibration analysis? Answer 3: The National Instruments PCI-4461 Sound and Vibration Device offers high-precision data acquisition with a 2-channel dynamic signal generator and acquisition system, featuring AC/DC configurable coupling, integrated IEPE conditioning, 24-bit resolution ADCs, multiple sampling rates up to 192 kS/s, a delta-sigma ADC type with an input gain range of -20 to +30 dB, an impressive 118 dB dynamic range, a frequency range from DC to 92 kHz, and a low
Question 4: What are the key specifications of the National Instruments PCI-4461 Sound and Vibration Device that make it suitable for high-precision sound and vibration analysis? Answer 4: The National Instruments PCI-4461 Sound and Vibration Device is suitable for high-precision sound and vibration analysis due to its integrated 2-channel dynamic signal generation and acquisition, AC/DC configurable coupling, integrated IEPE conditioning, 24-bit resolution ADCs with multiple sampling rates up to 192 kS/s, an input gain range of -20 to +30 dB, a 118 dB dynamic range, a frequency range from DC to 92 kHz, and a typical Total Harmonic Dist
Question 5: What features make the National Instruments PCI-4461 Sound and Vibration Device suitable for high-precision data acquisition in sound and vibration analysis? Answer 5: The National Instruments PCI-4461 Sound and Vibration Device is suitable for high-precision data acquisition in sound and vibration analysis due to its two-channel dynamic signal generation and acquisition, AC/DC configurable coupling, integrated IEPE conditioning, 24-bit resolution ADCs with multiple sampling rates up to 192 kS/s, a delta-sigma ADC type with an input gain range of -20 to +30 dB, a dynamic range of 118 dB, a frequency range up to 92 kHz