The National Instruments PCI-4552 is a dynamic signal acquisition device offering 4 analog inputs with 16-bit resolution, a 204.8 kS/s sampling rate, and an input range of ±10 mV to ±42.4 V


Description

The National Instruments PCI-4552 Dynamic Signal Acquisition Device is engineered to provide high-precision analog and digital signal processing with its 4 analog inputs, 16-bit input resolution, and a sampling rate of 204.8 kS/s. It supports a wide input range from ±10 mV to ±42.4 V and offers flexible input configuration options, including differential and single-ended inputs.

This device features 8 digital I/O channels and supports both analog and digital triggering mechanisms. The input mode is adaptable, allowing for differential (DIFF) inputs, and can be configured for referenced single-ended (SE) measurements with the BNC-2140 accessory.

Users can configure the trigger circuit to monitor an analog input channel for level trigger, with the trigger-level range corresponding to the analog input voltage range. Powered by NIDAQmx driver software, the PCI-4552 is compatible with various application development environments (ADEs) such as LabVIEW, LabWindows/CVI, Microsoft Visual C++, and Borland C++.

Configuration and management of the device is facilitated by the Measurement & Automation Explorer (MAX) software tool. With its compact physical dimensions, this acquisition device fits neatly into a range of setups, providing robust performance for complex data acquisition tasks.

Specification Details
Product Name National Instruments PCI-4552 Dynamic Signal Acquisition Device
Analog Inputs 4
Input Resolution 16 bits
Sampling Rate 204.8 kS/s
Input Range ±10 mV to ±42.4 V
Input Configuration Differential/Single Ended
Digital I/O 8
Triggering Analog/Digital
Input Mode Differential (DIFF), Configurable for Referenced Single-Ended (SE) with BNC-2140 Accessory
Trigger Circuit Configuration Configurable to Monitor an Analog Input Channel for Level Trigger
Trigger-Level Range Same as Analog Input Voltage Range
Driver Software NIDAQmx
Compatible ADEs LabVIEW, LabWindows/CVI, Microsoft Visual C++, Borland C++
Configuration Software Measurement & Automation Explorer (MAX)
Physical Dimensions 4.19 x 12.28 x

Q1: Based on the provided description, what is the role of the Measurement & Automation Explorer (MAX) software tool in the operation of the National Instruments PCI-4552 Dynamic Signal Acquisition Device?
A1: The National Instruments PCI-4552 Dynamic Signal Acquisition Device supports differential (DIFF) input modes and can be configured for referenced single-ended (SE) measurements with the use of the BNC-2140 accessory.

Q2: What input modes are supported by the National Instruments PCI-4552 Dynamic Signal Acquisition Device, and can it be configured with the BNC-2140 accessory for referenced single-ended measurements?
A2: The Measurement & Automation Explorer (MAX) software tool facilitates the configuration and management of the National Instruments PCI-4552 Dynamic Signal Acquisition Device, helping users to effectively set up and control the device’s operations for their data acquisition tasks.

Q3: What are the input configuration options provided by the National Instruments PCI-4552 Dynamic Signal Acquisition Device for handling analog signals?
A3: The National Instruments PCI-4552 Dynamic Signal Acquisition Device boasts a 16-bit input resolution and a sampling rate of 204.8 kS/s for its analog inputs, and it is compatible with software environments including LabVIEW, LabWindows/CVI, Microsoft Visual C++, and Borland C++.

Q4: What input modes does the National Instruments PCI-4552 Dynamic Signal Acquisition Device support, and which accessory is required for configuring referenced single-ended measurements?
A4: The National Instruments PCI-4552 Dynamic Signal Acquisition Device offers flexible input configuration options for handling analog signals, including differential and single-ended inputs, as well as the ability to configure for referenced single-ended measurements when used with the BNC-2140 accessory.

Q5: What are the capabilities of the National Instruments PCI-4552 Dynamic Signal Acquisition Device in terms of analog input resolution and sampling rate, and which software environments is it compatible with?
A5: The National Instruments PCI-4552 Dynamic Signal Acquisition Device supports differential and single-ended input modes, and it can indeed be configured with the BNC-2140 accessory for referenced single-ended measurements.