PCI-6014

The PCI-6014 is a multifunction DAQ with 16 single-ended or 8 differential input channels, dual 16-bit analog outputs, a sampling rate up to 200 kS/s, and features such as overvoltage protection,

In Stock | Ships Today

img

    Description

    The National Instruments PCI-6014, with Part Number 778627-01, is a versatile Multifunction Data Acquisition Device (DAQ) that supports both single-ended and differential input configurations, offering 16 Single-ended or 8 Differential Input Channels. It provides 2 Analog Output channels, each with a 16-bit resolution, and has an input range from ±0.05 to ±10 V and an output range of ±10 V.

    This DAQ device is capable of a sampling rate of 200 kS/s for input and 10 kS/s for output, ensuring efficient data capture and processing. It includes two 24-bit up/down counters/timers and eight digital I/O channels, expanding its applicability in various timing I/O functions. The Successive approximation ADC type ensures precise data conversion from analog to digital form.

    With regard to safety, the PCI-6014 is equipped with overvoltage protection during operation at ±25 V and in an idle state at ±15 V, protecting the device from potential damage from unexpected voltage spikes. It features one DMA channel with a 512 words configuration memory size and a 512 samples FIFO buffer size, which enhances its data handling capabilities. Lastly, it supports various data transfer modes, including interrupts, DMA, and programmed I/O, ensuring flexibility and compatibility with different system configurations.

    Feature Description
    Part Number PCI-6014 (778627-01)
    Type Multifunction Data Acquisition Device (DAQ)
    Input Channels 16 Single-ended or 8 Differential
    Analog Outputs 2 channels at 16 bits
    Input Range ±0.05 to ±10 V
    Output Range ±10 V
    Sampling Rate (Input) 200 kS/s
    Sampling Rate (Output) 10 kS/s
    Counters/Timers Two 24 bit up/down
    Digital I/O Eight channels
    ADC Type Successive approximation ADC
    Overvoltage Protection (Operating) ±25 V
    Overvoltage Protection (Idle) ±15 V
    DMA Channels 1 channel with 512 words configuration memory
    Buffer Size 512 samples FIFO
    Data Transfer Modes Interrupts, DMA, Programmed

    Question 1: What is the input voltage range and the number of analog output channels provided by the National Instruments PCI-6014 Multifunction Data Acquisition Device?
    Answer 1: The National Instruments PCI-6014 uses Successive Approximation ADC for precise data conversion from analog to digital form.

    Question 2: What is the maximum overvoltage protection provided by the National Instruments PCI-6014 during operation and in idle state?
    Answer 2: The National Instruments PCI-6014 provides maximum overvoltage protection of ±25 V during operation and ±15 V in an idle state.

    Question 3: What is the maximum input and output sampling rate of the National Instruments PCI-6014 Multifunction Data Acquisition Device?
    Answer 3: The National Instruments PCI-6014 DAQ device offers 16 single-ended or 8 differential input channels with an input range of ±0.05 to ±10 V, and 2 analog output channels with a 16-bit resolution and an output range of ±10 V.

    Question 4: What input and output specifications, including ranges and resolutions, does the National Instruments PCI-6014 DAQ device offer?
    Answer 4: The maximum input sampling rate of the National Instruments PCI-6014 Multifunction Data Acquisition Device is 200 kS/s, and the maximum output sampling rate is 10 kS/s.

    Question 5: What type of analog-to-digital conversion does the National Instruments PCI-6014 use for precise data conversion?
    Answer 5: The National Instruments PCI-6014 Multifunction Data Acquisition Device provides an input voltage range of ±0.05 to ±10 V and offers 2 analog output channels.