img

PCI-6034E

The National Instruments PCI-6034E Multifunction DAQ, part number 778075-01, is a high-resolution 16-bit data acquisition card from the E Series with 16 single-ended or 8 differential analog inputs, a maximum

In Stock | Ships Today

img

    Description

    The National Instruments PCI-6034E Multifunction DAQ is a versatile device with a part number 778075-01, belonging to the E Series. It is designed to perform multifunction data acquisition tasks with high precision, offering 16 single-ended or 8 differential analog input channels that are software-selectable per channel, ensuring adaptability to various signal types.

    This DAQ device boasts an impressive 16 bits resolution and a maximum sampling rate of 200 kS/s, allowing for accurate and rapid data capture. Users can safely input signals within the ±11 V of ground range, minimizing the risk of damage due to overvoltage.

    It features multiple analog input signals, including ACH<0..15>, ASENSE, and AIGND, providing a robust interface for a wide range of sensors and signal sources. The device also includes 8 digital I/O lines, which can be individually programmed for either input or output, offering flexibility for various control and monitoring applications.

    Additionally, it is equipped with 2 general-purpose counters, enhancing its functionality in measurement and timing-related tasks. The 68-pin male SCSI-II type I/O connector ensures reliable and secure connectivity, while the RTSI bus enables seamless interconnection of timing signals amongst boards. The Programmable Function Inputs (PFI) are crucial for interfacing the board with external equipment, expanding its integration capabilities.

    For optimal performance, a recommended warm-up time is specified, ensuring that the device operates within its designed parameters, thereby maintaining accuracy and reliability over time.

    Question 1: What is the maximum sampling rate and resolution of the National Instruments PCI-6034E Multifunction DAQ, and how do these specifications contribute to its data acquisition capabilities?
    Answer 1: The provided description does not specify the exact recommended warm-up time for the National Instruments PCI-6034E Multifunction DAQ to ensure optimal performance.

    Question 2: What is the recommended warm-up time for the National Instruments PCI-6034E Multifunction DAQ to ensure it operates within its designed parameters for optimal performance?
    Answer 2: I’m sorry for any confusion, but the provided description does not specify the exact recommended warm-up time for the National Instruments PCI-6034E Multifunction DAQ. To obtain this information, you would need to consult the device’s user manual or technical specifications provided by National Instruments.

    Question 3: What is the recommended warm-up time for the National Instruments PCI-6034E Multifunction DAQ to ensure it operates within its designed parameters for accuracy and reliability?
    Answer 3: The National Instruments PCI-6034E Multifunction DAQ, part of the E Series with part number 778075-01, features 16 single-ended or 8 differential analog input channels with software-selectable per-channel settings, a 16-bit resolution, and a maximum sampling rate of 200 kS/s, which together enable precise and swift data acquisition. It supports a signal input range of ±11 V from ground, reducing overvoltage damage risks, and includes various analog input

    Question 4: What are the key features and specifications of the National Instruments PCI-6034E Multifunction DAQ that make it suitable for high-precision data acquisition tasks?
    Answer 4: The National Instruments PCI-6034E Multifunction DAQ has a maximum sampling rate of 200 kS/s and a resolution of 16 bits, which allow it to capture data accurately and quickly, making it highly effective for precision measurement and analysis tasks in various data acquisition applications.

    Question 5: What are the key features and specifications of the National Instruments PCI-6034E Multifunction DAQ, and how do they enhance its performance in data acquisition tasks?
    Answer 5: The National Instruments PCI-6034E Multifunction DAQ is suitable for high-precision data acquisition tasks due to its 16 single-ended or 8 differential analog input channels, 16-bit resolution, a maximum sampling rate of 200 kS/s, input signal range of ±11 V, 8 digital I/O lines, 2 general-purpose counters, a 68-pin male SCSI-II type I/O connector for reliable connectivity, RTSI bus for board synchronization, and Programmable Function

    Specification Detail
    Product Name National Instruments PCI-6034E Multifunction DAQ
    Part Number 778075-01
    Series E Series
    Functionality Multifunction Data Acquisition (DAQ)
    Analog Input Channels 16 single-ended or 8 differential (software-selectable per channel)
    Resolution 16 bits
    Maximum Sampling Rate 200 kS/s
    Input Voltage Range ±11 V of ground
    Analog Input Signals ACH<0..15>, ASENSE, AIGND
    Digital I/O Lines 8 (programmable for input or output)
    Counters 2 general purpose counters (Counters 0 and 1)
    Connectivity 68-pin male SCSI-II type I/O connector
    RTSI Bus Used to interconnect timing signals amongst the boards
    Programmable Function Inputs (PFI) Used to interface the board to external equipment
    Recommended Warm-Up Time