Description
The National Instruments PCI-6115 Multifunction I/O Device, part of the S Series, comes with various part numbers including 778534-01, 778554-01, and 184529D-03, offering two FIFO buffer sizes of 16 MS and 32 MS respectively. It is equipped with four pseudo differential analog input channels and two analog output channels, both featuring 12 bit resolution. This device supports a maximum sampling rate of 10 MS/s per channel and a minimum of 20 kS/s per channel, with a maximum update rate of 4 MS/s on analog output.
Additionally, the PCI-6115 includes eight TTL/CMOS digital I/O channels and two 24-bit resolution counters, ensuring precise measurements. The absolute accuracy for the analog input channels is rated at 184 mV, and the device operates through a BUS power interface for easy integration into various systems.
Feature | Description |
---|---|
Manufacturer | National Instruments |
Product Line | S Series |
Model | PCI-6115 |
Part Numbers | 778534-01, 778554-01, 184529D-03 |
FIFO Buffer Size (778534-01) | 16 MS |
FIFO Buffer Size (778554-01) | 32 MS |
Analog Input Channels | 4 (pseudo differential) |
Resolution (Analog Input/Output) | 12 bit |
Sampling Rate (Max) | 10 MS/s per channel |
Sampling Rate (Min) | 20 kS/s per channel |
Analog Output Channels | 2 |
Max Update Rate (Analog Output) | 4 MS/s |
Digital I/O Channels | 8 TTL/CMOS |
Counters | 2 (24 bit resolution) |
Absolute Accuracy (Analog Input) | 184 mV |
Power Interface | BUS power |
Question 1: What are the differences in FIFO buffer sizes available for the National Instruments PCI-6115 Multifunction I/O Device, and how do they affect the device’s performance?
Answer 1: The National Instruments PCI-6115 Multifunction I/O Device offers two FIFO buffer sizes of 16 MS (megabytes) and 32 MS, which affect the device’s performance by determining the amount of data that can be stored temporarily during high-speed data acquisition, with larger buffers allowing for longer acquisition times without data loss or the need for continuous transfer to the host memory.
Question 2: What are the differences in FIFO buffer sizes available for the National Instruments PCI-6115 Multifunction I/O Device, and what is its rated absolute accuracy for analog input channels?
Answer 2: The National Instruments PCI-6115 Multifunction I/O Device is available with part numbers 778534-01, 778554-01, and 184529D-03, and features four pseudo differential analog input channels and two analog output channels, both with a 12-bit resolution. It supports a maximum sampling rate of 10 MS/s per channel and a minimum of 20 kS/s per channel, with a maximum analog output update rate of 4 MS/s. Additionally,
Question 3: What are the specifications and features of the National Instruments PCI-6115 Multifunction I/O Device, including its analog input and output channel resolutions, maximum sampling rates, digital I/O channels, and power interface type?
Answer 3: The National Instruments PCI-6115 Multifunction I/O Device offers two FIFO buffer sizes of 16 MS and 32 MS, and its rated absolute accuracy for analog input channels is 184 mV.
Question 4: What are the FIFO buffer sizes available for the National Instruments PCI-6115 Multifunction I/O Device, and what is its absolute accuracy rating for the analog input channels?
Answer 4: The National Instruments PCI-6115 Multifunction I/O Device offers FIFO buffer sizes of 16 MS and 32 MS, and the absolute accuracy rating for the analog input channels is 184 mV.
Question 5: What are the various part numbers for the National Instruments PCI-6115 Multifunction I/O Device, and what are its key specifications in terms of analog input/output channels, resolution, sampling and update rates, and digital I/O channels?
Answer 5: The National Instruments PCI-6115 Multifunction I/O Device, part of the S Series, features four pseudo differential analog input channels and two analog output channels with a 12-bit resolution, supports a maximum sampling rate of 10 MS/s per channel and a minimum of 20 kS/s per channel for inputs with a maximum update rate of 4 MS/s for outputs, includes eight TTL/CMOS digital I/O channels and two 24-bit resolution counters for precise measurements, and operates