Description
The National Instruments PCI-6230 from the M Series is a multifunction data acquisition board featuring bank isolation for enhanced noise rejection and safety. It boasts 8 single-ended or 4 differential analog inputs with a 16-bit resolution and a varied input range of ±10 V, ±5 V, ±1 V, and ±0.2 V, capable of a maximum sampling rate of 250 KS/s and a timing accuracy of 50 ppm.
With a bank isolation of up to 60 VDC and channel-to-bus isolation reaching up to 1950 VDC, this robust board ensures reliable performance in high-voltage environments. It also includes 4 analog output channels with a 16-bit output resolution and supports an impressive update rate of up to 500 kS/s per channel, while maintaining an output range of ±10 V.
Question 1: What are the key specifications and isolation features of the National Instruments PCI-6230 from the M Series?
Answer 1: The National Instruments PCI-6230 ensures safe and reliable performance in high-voltage environments through its bank isolation rated at up to 60 VDC and channel-to-bus isolation reaching up to 1950 VDC, which enhances noise rejection and user safety.
Question 2: What are the input and output features of the National Instruments PCI-6230 from the M Series, and how do its isolation specifications contribute to its performance in high-voltage environments?
Answer 2: The National Instruments PCI-6230 data acquisition board from the M Series features 8 single-ended or 4 differential analog inputs with a 16-bit resolution, offering a versatile input range of ±10 V, ±5 V, ±1 V, and ±0.2 V, and it provides bank isolation up to 60 VDC and channel-to-bus isolation of up to 1950 VDC, ensuring enhanced noise rejection and safe operation in high-voltage environments.
Question 3: How does the National Instruments PCI-6230 ensure safe and reliable performance in high-voltage environments?
Answer 3: The National Instruments PCI-6230 data acquisition board from the M Series features 8 single-ended or 4 differential analog inputs with a 16-bit resolution, offering input ranges of ±10 V, ±5 V, ±1 V, and ±0.2 V, and supports a maximum sampling rate of 250 KS/s with a timing accuracy of 50 ppm, along with bank isolation up to 60 VDC and channel-to-bus isolation of 1950 VDC for enhanced noise
Question 4: What are the features and capabilities of the National Instruments PCI-6230 data acquisition board from the M Series in terms of input range, resolution, and isolation specifications?
Answer 4: The National Instruments PCI-6230 from the M Series offers 8 single-ended or 4 differential analog inputs with a 16-bit resolution and input ranges of ±10 V, ±5 V, ±1 V, and ±0.2 V, capable of a maximum sampling rate of 250 KS/s, and 4 analog output channels with a 16-bit resolution and an update rate of up to 500 kS/s per channel with an output range of ±10 V. Its bank
Question 5: What are the features and capabilities of the National Instruments PCI-6230 data acquisition board from the M Series in terms of input range, resolution, sampling rate, and isolation specifications?
Answer 5: The National Instruments PCI-6230 from the M Series is a multifunction data acquisition board that offers 8 single-ended or 4 differential analog inputs with 16-bit resolution, a maximum sampling rate of 250 KS/s, and a timing accuracy of 50 ppm; it features bank isolation up to 60 VDC and channel-to-bus isolation up to 1950 VDC, as well as 4 analog output channels with 16-bit resolution and an update rate of 500 k
Specification | Detail |
---|---|
Manufacturer | National Instruments |
Product Line | M Series |
Part Number | 779615-01, 192236A-01 |
Type | Multifunction Data Acquisition Board |
Isolation | Bank Isolated |
Analog Inputs | 8 single-ended or 4 differential |
Resolution | 16 bit |
Input Range | ±10 V, ±5 V, ±1 V, ±0.2 V |
Sampling Rate | 250 KS/s max |
Timing Accuracy | 50 ppm |
Bank Isolation | Up to 60 VDC |
Channel-to-Bus Isolation | Up to 1950 VDC |
Analog Outputs | 4 channels |
Output Resolution | 16-bit |
Update Rate | 500 kS/s max per channel |
Output Range | ±10 V |