The National Instruments PCI-6517 Digital I/O Device, part number 779083-01, features 32 sink output lines, bank isolation, ±30 VDC maximum switching voltage, compatibility with NI-DAQmx, LabVIEW, and Lab


Description

The National Instruments PCI-6517 Digital I/O Device, part number 779083-01, is a robust piece of hardware that offers 32 sink output lines and features bank isolation for enhanced safety and functionality. This device is capable of handling a maximum switching voltage of ±30 VDC, making it ideal for various applications including data acquisition and industrial control.

It is designed to work seamlessly with multiple software packages, including NI-DAQmx, LabVIEW, and LabWindows/CVI, which support efficient and flexible programming environments. When operating at 25°C, the device can provide a maximum current of 75 mA per line when all 8 lines in a port are utilized, culminating in a maximum aggregate current of 600 mA per port. If not all lines are in use, each line can deliver up to 350 mA.

The hardware is equipped with a 37-pin male DSUB I/O connector for reliable connections. To ensure system integrity, it features digital I/O watchdogs, which are critical for monitoring and responding to system errors such as PCI bus failures or computer crashes, by setting the digital outputs to a safe state. Additionally, the device’s change detection feature and programmable input filters contribute to its ability to efficiently handle digital events and filter out noise without taxing the processor.

With a weight of just 2.5 oz and compact dimensions of 5.54 x 4.47 inches, the PCI-6517 is designed for easy integration into a variety of systems while maintaining a small footprint.

Feature Specification
Product Name National Instruments PCI-6517 Digital I/O Device
Part Number 779083-01
Output Lines 32 sink
Bank Isolation Yes
Maximum Switching Voltage ±30 VDC
Compatible Software NI-DAQmx, LabVIEW, LabWindows/CVI
Maximum Current per Line at 25°C (using all 8 lines in a port) 75 mA
Maximum Aggregate Current per Port 600 mA
Maximum Current per Line (if not all lines are used) 350 mA
I/O Connector 37-pin male DSUB
Digital I/O Watchdogs Yes
Change Detection Feature Yes
Programmable Input Filters Yes
Weight 2.5 oz
Dimensions (L x W) 5.54 x 4.47 in

Q1: What are the key features and capabilities of the National Instruments PCI-6517 Digital I/O Device, part number 779083-01, in terms of output lines, voltage handling, software compatibility, current delivery, connectivity, and safety measures?
A1: The National Instruments PCI-6517 Digital I/O Device supports a maximum switching voltage of ±30 VDC.

Q2: What is the maximum switching voltage supported by the National Instruments PCI-6517 Digital I/O Device?
A2: The function of the digital I/O watchdogs on the National Instruments PCI-6517 Digital I/O Device is to monitor the system for errors such as PCI bus failures or computer crashes and to set the digital outputs to a safe state in response to such events, thereby ensuring system integrity.

Q3: What are the capabilities and safety features of the National Instruments PCI-6517 Digital I/O Device with part number 779083-01 in terms of output lines, isolation, maximum voltage, and current?
A3: The National Instruments PCI-6517 Digital I/O Device, part number 779083-01, is equipped with 32 sink output lines, can manage a maximum switching voltage of ±30 VDC, and is compatible with software such as NI-DAQmx, LabVIEW, and LabWindows/CVI for versatile programming environments; it can deliver a maximum of 75 mA per line at 25°C with a total of 600 mA per port, or 350 mA per line if fewer lines

Q4: What are the key features and specifications of the National Instruments PCI-6517 Digital I/O Device, including its output capabilities, software compatibility, safety measures, and physical characteristics?
A4: The National Instruments PCI-6517 Digital I/O Device is a high-performance hardware component with 32 sink output lines, bank isolation for safety, and a ±30 VDC maximum switching voltage, suitable for data acquisition and industrial control. It supports NI-DAQmx, LabVIEW, and LabWindows/CVI software for flexible programming and offers a maximum current of 75 mA per line, or up to 350 mA if fewer lines are used, with a total of 600 mA per port.

Q5: What is the function of the digital I/O watchdogs on the National Instruments PCI-6517 Digital I/O Device?
A5: The National Instruments PCI-6517 Digital I/O Device, part number 779083-01, is equipped with 32 sink output lines, offers bank isolation for improved safety, can handle a maximum switching voltage of ±30 VDC, and provides up to 75 mA per line at 25°C when all 8 lines in a port are used, with a maximum aggregate current of 600 mA per port, or up to 350 mA when fewer lines are utilized.