Description
The National Instruments PCI-MIO-16XE-10, also known as PCI-6030E with part number 777384-01, is a versatile Multifunction DAQ device. It offers 16 analog inputs in single-ended mode or 8 in differential mode, complemented by 2 analog output channels with a resolution of 16 bits. Additionally, the device includes 8 digital I/O lines compatible with 5 V CMOS/TTL and features two 24-bit up/down counters.
Capable of a maximum sampling rate of 100 kS/s, this DAQ device ensures efficient data acquisition. It connects via a 68-pin male SCSI-II connector and is conveniently powered by the host PCI slot, negating the need for an external power supply. Software compatibility is broad, supporting the NIDAQ 7 driver, LabVIEW, Measurement Studio, and LabWindows/CVI.
The PCI-MIO-16XE-10 is designed with onboard self-calibration which is software controlled, although an external calibration is recommended either annually or every two years to maintain accuracy and performance.
Specification | Details |
---|---|
Manufacturer | National Instruments |
Product Name | PCI-MIO-16XE-10 |
Alternative Name | PCI-6030E |
Part Number | 777384-01 |
Type | Multifunction DAQ |
Analog Inputs | 16 (Single-ended), 8 (Differential) |
Analog Output Channels | 2 (16 bits resolution) |
Digital I/O Lines | 8 (5 V CMOS/TTL compatible) |
Counters | Two 24-bit up/down counters |
Maximum Sampling Rate | 100 kS/s |
Connector Type | 68-pin male SCSI-II |
Power Requirement | Powered by host PCI slot |
Software Compatibility | NIDAQ 7 driver, LabVIEW, Measurement Studio, LabWindows/CVI |
Onboard Calibration | Self-calibration (software controlled) |
Recommended Calibration Period | Annually or every two years |
Question 1: What are the specifications and recommended calibration frequency for the National Instruments PCI-MIO-16XE-10 (PCI-6030E) Multifunction DAQ device?
Answer 1: External calibration is recommended for the National Instruments PCI-MIO-16XE-10 either annually or every two years to ensure maintained accuracy and performance.
Question 2: How often is external calibration recommended for the National Instruments PCI-MIO-16XE-10 to ensure maintained accuracy and performance?
Answer 2: The National Instruments PCI-MIO-16XE-10, also known as the PCI-6030E, features 16 analog inputs in single-ended mode or 8 in differential mode, 2 analog output channels with 16-bit resolution, 8 digital I/O lines, two 24-bit up/down counters, and a maximum sampling rate of 100 kS/s, with onboard self-calibration; it is recommended that an external calibration be performed either annually or every two years to ensure continued
Question 3: What are the functions and features of the National Instruments PCI-MIO-16XE-10 (PCI-6030E) Multifunction DAQ device with part number 777384-01, and what software does it support?
Answer 3: The National Instruments PCI-MIO-16XE-10 (PCI-6030E) Multifunction DAQ device, part number 777384-01, functions as a data acquisition unit with 16 analog inputs (single-ended) or 8 (differential mode), 2 analog output channels with 16-bit resolution, 8 digital I/O lines compatible with 5 V CMOS/TTL, and two 24-bit up/down counters, supporting a maximum sampling rate of 100
Question 4: What are the characteristics and recommended calibration interval for the National Instruments PCI-MIO-16XE-10, also known as PCI-6030E?
Answer 4: The National Instruments PCI-MIO-16XE-10 (PCI-6030E) Multifunction DAQ device features 16 analog inputs in single-ended mode or 8 in differential mode, 2 analog output channels with 16-bit resolution, 8 digital I/O lines compatible with 5 V CMOS/TTL, and two 24-bit up/down counters, with a maximum sampling rate of 100 kS/s, connecting via a 68-pin male SCSI-II connector. It
Question 5: What is the maximum sampling rate and type of connector used by the National Instruments PCI-MIO-16XE-10 DAQ device?
Answer 5: The maximum sampling rate of the National Instruments PCI-MIO-16XE-10 DAQ device is 100 kS/s, and it uses a 68-pin male SCSI-II connector.