The National Instruments PCMCIA-5102 is a dual-channel digitizer with a Type II PCMCIA card form factor, featuring a 15 MHz bandwidth per channel, onboard memory of 663,000 samples, and compatibility with various software including


Phone: 1-800-915-6216

Email: sales@apexwaves.com

Description

The National Instruments PCMCIA-5102 Digitizer is a highly capable device that offers dual-channel, single-ended analog input channels, and operates as a Type II PCMCIA card suitable for various applications. It provides a wide bandwidth of 15 MHz per channel and accommodates a flexible voltage range from ± 50 mV to ± 5 V, with software-selectable AC and DC input coupling to adapt to different signal types.

With compatibility across a range of software including NI-DAQ, NI-SCOPE, LabVIEW, LabWindows, Visual Basic, and Measurement Studio, the PCMCIA-5102 facilitates integration into a variety of measurement and testing setups and is designed to function seamlessly with Windows operating systems.

The device is equipped with a substantial onboard memory capable of storing up to 663,000 samples, allowing for extensive data collection before transferring to the host computer. It also features advanced triggering capabilities, including hysteresis values, bi-level triggering, trigger hold-off, and programmable trigger thresholds, alongside two digital TTL/CMOS triggers for synchronizing with additional modules.

Ensuring precise measurements, the PCMCIA-5102 includes an 8-bit resolution analog-to-digital converter (ADC), and it is recommended to allow a 15-minute warm-up time for optimal performance. Regular maintenance includes external calibration annually and internal calibration whenever there are changes in environmental conditions, ensuring accuracy and reliability over the long term.

Specification Details
Manufacturer National Instruments
Product Name PCMCIA-5102 Digitizer
Channels Dual-channel, Single-ended analog input channels
PCMCIA Type Type II PCMCIA card
Software Compatibility NI-DAQ, NI-SCOPE, LabVIEW, LabWindows, Visual Basic, Measurement Studio
Operating System Compatibility Windows
Bandwidth per Channel 15 MHz
Voltage Range ± 50 mV to ± 5 V
Input Coupling Software-selectable AC and DC
Onboard Memory 663,000 samples
Triggering Capabilities Hysteresis values, bi-level triggering, trigger hold-off, programmable trigger thresholds
Digital Triggers Two digital TTL/CMOS
Resolution 8-bit ADC
Warm-up Time 15 minutes recommended
Calibration External calibration annually, internal calibration with environmental changes

Q1: What are the benefits of the National Instruments PCMCIA-5102 Digitizer’s on-board memory capacity and advanced triggering capabilities for data collection and synchronization?
A1: The National Instruments PCMCIA-5102 Digitizer’s substantial onboard memory allows for the collection of up to 663,000 samples without the need for immediate transfer to a host computer, enhancing data acquisition efficiency, while its advanced triggering capabilities offer precise control over the start of data capture and synchronization with other devices, leading to more accurate and reliable measurements in complex testing and measurement setups.

Q2: What are the primary features and compatibility options of the National Instruments PCMCIA-5102 Digitizer, and what practices are recommended to maintain its accuracy and reliability over time?
A2: The National Instruments PCMCIA-5102 Digitizer offers advanced triggering capabilities including hysteresis values, bi-level triggering, trigger hold-off, and programmable trigger thresholds, as well as two digital TTL/CMOS triggers for synchronization with additional modules, and it ensures precise measurements over time through its 8-bit resolution analog-to-digital converter (ADC) and by recommending external calibration annually and internal calibration when environmental conditions change.

Q3: What are the advanced triggering capabilities of the National Instruments PCMCIA-5102 Digitizer, and how does it ensure precise measurements over time?
A3: The National Instruments PCMCIA-5102 Digitizer boasts primary features such as dual-channel, single-ended analog input channels, a 15 MHz bandwidth per channel, a flexible voltage range from ±50 mV to ±5 V, onboard memory for up to 663,000 samples, advanced triggering capabilities, and an 8-bit ADC; it is compatible with a variety of software including NI-DAQ, NI-SCOPE, LabVIEW, and operates with Windows OS. To maintain its accuracy

Q4: What are the key features and software compatibility of the National Instruments PCMCIA-5102 Digitizer that make it suitable for various applications?
A4: The recommended maintenance practices for the National Instruments PCMCIA-5102 Digitizer to ensure its accuracy and reliability over time include performing external calibration annually and conducting internal calibration whenever there are changes in environmental conditions.

Q5: What specific maintenance practices are recommended for the National Instruments PCMCIA-5102 Digitizer to guarantee its accuracy and reliability over time?
A5: The National Instruments PCMCIA-5102 Digitizer boasts key features such as dual-channel, single-ended analog input channels with a 15 MHz bandwidth per channel, a flexible voltage range from ±50 mV to ±5 V, software-selectable AC/DC input coupling, and advanced triggering capabilities; it is compatible with a range of software including NI-DAQ, NI-SCOPE, LabVIEW, LabWindows, Visual Basic, and Measurement Studio, making it versatile for various measurement and testing