PXI-1002

The National Instruments PXI-1002 chassis, with part number 778114-01, features 4 slots plus 3 expansion slots, supports a wide input voltage range, offers 170 W of power, and includes advanced synchronization capabilities, dual

In Stock | Ships Today

img

    Description

    The National Instruments PXI-1002 with Part Number 778114-01 offers a flexible configuration with 4 chassis slots, including 3 peripheral slots and 1 controller slot, in addition to 3 controller expansion slots. It supports a wide input voltage range of 90 to 135 or 180 to 265 VAC, with an input frequency of 47 to 63 Hz, delivering a maximum usable output power of 170 W.

    This chassis provides robust backplane support for PXI specification defined trigger signals, high-precision synchronization, star trigger bus, module-to-module local buses, and a 10 MHz reference clock, catering to a variety of synchronization needs. The system is kept cool by two cooling fans, each providing 60 cfm of airflow with filters, contributing to a total cooling capacity of 300 W.

    Durability is a key feature, with a MTBF (Mean Time Between Failures) rated at 115,000 hours in AC mode and 79,000 hours in AC/DC mode. Installation is made easy with an optional rack-mount kit designed for 19-inch rack setups. The chassis is relatively lightweight, tipping the scales at 9.5 lb, and its physical dimensions are 8.4 x 10.1 x 7.5 inches, making it compact yet robust. It operates efficiently within a temperature range of 0 to 50 °C, ensuring reliability across various environments.

    Question 1: What are the voltage ranges and input frequency supported by the National Instruments PXI-1002, and what is its maximum usable output power?
    Answer 1: The National Instruments PXI-1002’s backplane supports PXI specification defined trigger signals, high-precision synchronization, star trigger bus, module-to-module local buses, and a 10 MHz reference clock to cater to various synchronization and signal triggering needs.

    Question 2: What types of synchronization and signal triggering capabilities are supported by the National Instruments PXI-1002’s backplane?
    Answer 2: The National Instruments PXI-1002 offers a maximum usable output power of 170 W, and its backplane support enhances synchronization capabilities by providing PXI specification defined trigger signals, star trigger bus, module-to-module local buses, and a 10 MHz reference clock for high-precision synchronization.

    Question 3: What is the maximum usable output power of the National Instruments PXI-1002, and how does its backplane support enhance synchronization capabilities?
    Answer 3: The National Instruments PXI-1002 chassis supports an input voltage range of 90 to 135 or 180 to 265 VAC at an input frequency of 47 to 63 Hz, with a maximum usable output power of 170 W, and it operates efficiently within a temperature range of 0 to 50 °C for optimal operation.

    Question 4: What are the input voltage and frequency specifications, as well as the maximum usable output power for the National Instruments PXI-1002 with Part Number 778114-01?
    Answer 4: The National Instruments PXI-1002 supports an input voltage range of 90 to 135 or 180 to 265 VAC and an input frequency of 47 to 63 Hz, with a maximum usable output power of 170 W.

    Question 5: What power requirements and environmental conditions does the National Instruments PXI-1002 chassis support for optimal operation?
    Answer 5: The National Instruments PXI-1002 with Part Number 778114-01 supports an input voltage range of 90 to 135 or 180 to 265 VAC, an input frequency of 47 to 63 Hz, and delivers a maximum usable output power of 170 W.

    Specification Detail
    Part Number 778114-01
    Chassis Slots 4 slots (3 peripheral, 1 controller) and 3 controller expansion slots
    Input Voltage 90 to 135 or 180 to 265 VAC
    Input Frequency 47 to 63 Hz
    Output Power 170 W maximum usable
    Backplane Support PXI specification defined trigger signals, high-precision synchronization, star trigger bus, module-to-module local buses, 10 MHz reference clock
    Cooling Fans 2 fans, 60 cfm each with filters
    Total Cooling Capacity 300 W
    MTBF (Mean Time Between Failures) 115,000 hours (AC mode), 79,000 hours (AC/DC mode)
    Installation Options Optional rack-mount kit for 19 inch rack installation
    Weight 9.5 lb
    Physical Dimensions (W x D x H) 8.4 x 10.1 x 7.5 inches
    Operating Temperature Range 0 to 50 °C