img

PXI-1409

The National Instruments PXI-1409, with part number 778336-01, is an IMAQ device featuring four configurable control lines, support for four video sources, advanced chrominance removal, a 1,024 x 10-bit

In Stock | Ships Today

img

    Description

    The National Instruments PXI-1409, with part number 778336-01, features four configurable control lines designed to generate precise timing signals essential for camera acquisition. It supports up to four video sources and includes four external I/O lines that can be utilized as triggers or for digital input/output purposes.

    An advanced channel is available on the device to remove chrominance from composite color video signals complying with both PAL and NTSC standards. The PXI-1409 processes signals through a 1,024 x 10-bit Lookup Table (LUT), allowing the implementation of image operations such as contrast enhancement, gamma correction, or other custom transfer functions.

    This IMAQ device boasts an onboard memory of 16 MB SDRAM and is equipped with three independent direct memory access (DMA) controllers that support scatter-gather DMA, enabling efficient data transfers to the system memory.

    The integrated genlock circuit is capable of syncing with standard RS-170/NTSC and CCIR/PAL video signals, as well as generating progressive scan and VGA resolution signals. The PXI-1409 is designed for seamless integration with the NI-IMAQ driver software and is compatible with various programming environments, including LabVIEW, LabWindows/CVI, and Microsoft Visual Basic.

    With a lightweight build of just 0.38 lb and compact dimensions of 3.9 x 6.3 inches, the PXI-1409 operates efficiently within a temperature range of 0 °C to 55 °C, making it a versatile and reliable choice for various imaging applications.

    National Instruments PXI-1409 Technical Specifications
    Part Number 778336-01
    Control Lines 4 configurable lines for timing signals
    Video Sources Supported 4
    External I/O Lines 4 (triggers or digital I/O)
    Advanced Channel Chrominance removal for PAL/NTSC
    Lookup Table (LUT) 1,024 x 10-bit
    Video Input Impedance 75 ohms
    Onboard Memory 16 MB SDRAM
    Direct Memory Access (DMA) Controllers 3 independent onboard with scatter-gather DMA
    Genlock Circuit Supports RS-170/NTSC, CCIR/PAL, progressive scan, VGA signals
    Software Compatibility NI-IMAQ driver software; compatible with LabVIEW, LabWindows/CVI, Microsoft Visual Basic
    Weight 0.38 lb
    Dimensions 3.9 x 6.3 in.
    Operating Temperature Range 0 °C to 55 °C
    Storage Temperature

    Question 1: How does the National Instruments PXI-1409’s genlock circuit enhance synchronization with video signals, and which programming environments is it compatible with?
    Answer 1: The National Instruments PXI-1409’s genlock circuit enhances synchronization with video signals by syncing with standard RS-170/NTSC and CCIR/PAL video signals, as well as generating progressive scan and VGA resolution signals, and it is compatible with programming environments such as LabVIEW, LabWindows/CVI, and Microsoft Visual Basic.

    Question 2: What are the capabilities and specifications of the National Instruments PXI-1409, with particular reference to its compatibility with video standards, onboard memory, and support for various programming environments?
    Answer 2: The National Instruments PXI-1409, with part number 778336-01, is equipped with four configurable control lines for precise timing signals, supports four video sources, and offers four external I/O lines for triggers or digital I/O, enhancing its versatility in imaging applications. It features an advanced channel that removes chrominance from PAL and NTSC color video signals, a 1,024 x 10-bit LUT for image processing tasks such as contrast enhancement and gamma correction, and 16

    Question 3: How does the National Instruments PXI-1409 enhance image operations through its Lookup Table, and what types of video standards are compatible with its advanced channel feature?
    Answer 3: The National Instruments PXI-1409 enhances image operations by using a 1,024 x 10-bit Lookup Table (LUT) to implement image operations like contrast enhancement, gamma correction, or other custom transfer functions, and its advanced channel feature is compatible with both PAL and NTSC video standards for removing chrominance from composite color video signals.

    Question 4: What are the capabilities and specifications of the National Instruments PXI-1409, and how do these features contribute to its performance in imaging applications?
    Answer 4: The National Instruments PXI-1409 processes signals using a 1,024 x 10-bit Lookup Table (LUT), enabling it to perform image operations like contrast enhancement and gamma correction, and its advanced channel complies with both PAL and NTSC standards for removing chrominance from composite color video signals.

    Question 5: How does the National Instruments PXI-1409 process signals to implement image operations, and which standards does its advanced channel comply with for removing chrominance from composite color video signals?
    Answer 5: The National Instruments PXI-1409 is capable of handling up to four video sources with four configurable control lines for precise timing signals, and it supports both PAL and NTSC standards through an advanced channel that removes chrominance from composite color video signals. It processes signals using a 1,024 x 10-bit Lookup Table for image operations and boasts 16 MB SDRAM with three DMA controllers for efficient data transfers. The device is compatible with programming environments such as LabVIEW, LabWindows/CVI