Description
The National Instruments PXI-1470 PXI Vector Signal Analyzer is a comprehensive solution that includes various modules such as the PXIe-5622 IF Digitizer Module, PXI-1430C RF Downconverter Module, PXI-1450B Oscillator Source Module, PXI-1420 MW Downconverter Module, and the PXI-1410 Pre-selector Module. This analyzer boasts a robust frequency range of up to 26.5 GHz and comes equipped with 256 MB of internal storage. Regular maintenance is made hassle-free with a calibration interval of one year, and it requires a warm-up time of only 20 minutes before use.
Power efficiency is a key aspect of the PXI-1470, with the PXI-1420 module consuming a minimum of 11 W and the PXIe-5622 module requiring a maximum of 33 W. The instrument’s resolution bandwidth is versatile, ranging from 100 Hz to 50 MHz, and it supports various triggering modes such as software edge, I/Q power edge, digital, and disable edge to accommodate different testing scenarios.
Compatibility with modern operating systems is ensured, as the PXI-1470 supports Windows Vista/7/8/8.1, provided that all necessary updates and service packs are installed. To operate this analyzer, the NI-RFSA 2.9 instrument driver is required, along with additional software support specifically for the PXI-1470. This setup ensures users can maximize the potential of this powerful signal analyzing tool.
Question 1: What is the frequency range and internal storage capacity of the National Instruments PXI-1470 PXI Vector Signal Analyzer, and what operating systems does it support?
Answer 1: The National Instruments PXI-1470 PXI Vector Signal Analyzer supports software edge, I/Q power edge, digital, and disable edge triggering modes to accommodate various testing scenarios.
Question 2: What types of triggering modes does the National Instruments PXI-1470 PXI Vector Signal Analyzer support for accommodating various testing scenarios?
Answer 2: The National Instruments PXI-1470 PXI Vector Signal Analyzer has a frequency range of up to 26.5 GHz and includes 256 MB of internal storage, featuring modules such as the PXIe-5622 IF Digitizer Module, PXI-1430C RF Downconverter Module, PXI-1450B Oscillator Source Module, PXI-1420 MW Downconverter Module, and the PXI-1410 Pre-selector Module.
Question 3: What is the maximum power consumption of the PXIe-5622 module within the National Instruments PXI-1470 PXI Vector Signal Analyzer?
Answer 3: The maximum power consumption of the PXIe-5622 module within the National Instruments PXI-1470 PXI Vector Signal Analyzer is 33 watts.
Question 4: What is the maximum frequency range and internal storage capacity of the National Instruments PXI-1470 PXI Vector Signal Analyzer, and which modules are included as part of this comprehensive solution?
Answer 4: The National Instruments PXI-1470 PXI Vector Signal Analyzer has a frequency range of up to 26.5 GHz, an internal storage capacity of 256 MB, and supports Windows Vista/7/8/8.1 operating systems.
Question 5: What is the frequency range and internal storage capacity of the National Instruments PXI-1470 PXI Vector Signal Analyzer, and which specific modules does it include?
Answer 5: The National Instruments PXI-1470 PXI Vector Signal Analyzer has a maximum frequency range of up to 26.5 GHz and an internal storage capacity of 256 MB, and it includes the PXIe-5622 IF Digitizer Module, PXI-1430C RF Downconverter Module, PXI-1450B Oscillator Source Module, PXI-1420 MW Downconverter Module, and the PXI-1410 Pre-selector Module as part of its comprehensive solution.
Specification | Detail |
---|---|
Manufacturer | National Instruments |
Product Name | PXI-1470 PXI Vector Signal Analyzer |
Modules Included | PXIe-5622 IF Digitizer Module, PXI-1430C RF Downconverter Module, PXI-1450B Oscillator Source Module, PXI-1420 MW Downconverter Module, PXI-1410 Pre-selector Module |
Frequency Range | Up to 26.5 GHz |
Internal Storage | 256 MB |
Calibration Interval | 1 year |
Warm-up Time | 20 minutes |
Power Consumption | PXI-1420: Minimum 11 W, PXIe-5622: Maximum 33 W |
Resolution Bandwidth | 100 Hz – 50 MHz |
Triggering Modes | Software edge, I/Q power edge, digital, disable edge |
Supported Operating Systems | Windows Vista/7/8/8.1 (with all updates and service packs) |
Required Instrument Driver | NI-RFSA 2.9 |
Additional Required Software | PXI-1470 Support |