img

PXI-2514

The National Instruments PXI-2514 is a PXI Signal Insertion Switch Module designed as a Fault Insertion Unit for hardware in the loop and electronic reliability testing, with capabilities for symmetrical connection faults and shorts, compatible with LabVIEW Real-Time

In Stock | Ships Today

img

    Description

    The National Instruments PXI-2514 PXI Signal Insertion Switch Module serves as a Fault Insertion Unit (FIU), designed for applications such as Hardware in the Loop (HIL) and electronic reliability testing. It features direct-feed channels that can be dynamically opened or closed to failover buses, providing versatile fault insertion capabilities including symmetrical open/interfered connections, shorts between pins, shorts to battery voltages, and shorts to ground.

    Identified by its part number 778572-14, this module is compatible with the LabVIEW Real-Time Module, enhancing its suitability for real-time applications. It supports backplane triggering, enabling the module to send and receive triggers that facilitate the simulation of fault conditions and enhance automated test coverage.

    For software interaction, the PXI-2514 can be used with the NI-SWITCH Soft Front Panel on Windows, and for automated control, the NI-SWITCH hardware driver provides comprehensive module functionality. Despite entering the End of Life (EOL) Maintenance phase on June 30, 2022, the module remains available through Apex Waves, which continues to support the product.

    Specification Detail
    Product Name National Instruments PXI-2514 PXI Signal Insertion Switch Module
    Function Fault Insertion Unit (FIU)
    Applications Hardware in the loop (HIL), Electronic reliability testing
    Channels Direct-feed channels with open/close to failover buses
    Fault Insertion Capabilities Symmetrical open/interfered connections, shorts between pins, shorts to battery voltages, shorts to ground
    Part Number 778572-14
    LabVIEW Real-Time Module Compatibility Yes
    Backplane Triggering Send and receive triggers for fault conditions and test coverage
    Software Interaction NI-SWITCH Soft Front Panel for Windows; NI-SWITCH hardware driver for automated control
    End of Life (EOL) Maintenance June 30, 2022
    Availability Available with Apex Waves

    Question 1: How does the National Instruments PXI-2514 PXI Signal Insertion Switch Module facilitate real-time hardware in the loop and electronic reliability testing applications?
    Answer 1: The National Instruments PXI-2514 PXI Signal Insertion Switch Module provides capabilities for simulating various fault conditions in electronic reliability testing and HIL applications, including dynamic opening or closing of direct-feed channels for failover buses, creating symmetrical open/interfered connections, shorts between pins, and shorts to battery voltages or ground.

    Question 2: What are the specialized fault insertion capabilities of the National Instruments PXI-2514 PXI Signal Insertion Switch Module, and how does its compatibility with the LabVIEW Real-Time Module and support from Apex Waves despite its End of Life status benefit users in HIL and electronic reliability testing?
    Answer 2: The National Instruments PXI-2514 PXI Signal Insertion Switch Module is designed for applications such as Hardware in the Loop (HIL) and electronic reliability testing, with unique fault insertion capabilities that include creating symmetrical open/interfered connections, shorts between pins, shorts to battery voltages, and shorts to ground through its direct-feed channels.

    Question 3: What capabilities does the National Instruments PXI-2514 PXI Signal Insertion Switch Module provide for simulating fault conditions in electronic reliability testing and HIL applications?
    Answer 3: The National Instruments PXI-2514 PXI Signal Insertion Switch Module facilitates real-time hardware in the loop (HIL) and electronic reliability testing applications by providing versatile fault insertion capabilities, such as the ability to dynamically open or close direct-feed channels for simulating faults like open connections, shorts between pins, and shorts to battery or ground, and by supporting backplane triggering, which enables the module to send and receive triggers to simulate fault conditions, all while being compatible with the LabVIEW Real-Time

    Question 4: What are the key features and applications of the National Instruments PXI-2514 PXI Signal Insertion Switch Module, and how does its compatibility with the LabVIEW Real-Time Module and support from Apex Waves affect its usability beyond the End of Life Maintenance phase?
    Answer 4: The National Instruments PXI-2514 PXI Signal Insertion Switch Module offers specialized fault insertion capabilities such as creating symmetrical open/interfered connections, shorts between pins, shorts to battery voltages, and shorts to ground, through its direct-feed channels; its compatibility with the LabVIEW Real-Time Module allows for seamless integration into real-time applications, and despite its End of Life status, users benefit from continued support and availability through Apex Waves, ensuring that their HIL and electronic reliability testing needs

    Question 5: What testing applications is the National Instruments PXI-2514 PXI Signal Insertion Switch Module designed for, and what are its unique fault insertion capabilities?
    Answer 5: The National Instruments PXI-2514 PXI Signal Insertion Switch Module is a Fault Insertion Unit (FIU) featuring direct-feed channels for versatile fault insertion in Hardware in the Loop (HIL) and electronic reliability testing, with capabilities for creating symmetrical open/interfered connections, shorts between pins, and shorts to battery voltages or ground. Identified by part number 778572-14, its compatibility with the LabVIEW Real-Time Module ensures it is suitable for real-time applications