Description
The National Instruments PXI-2555, with part number 778572-55, is a PXI RF Multiplexer Switch Module designed for demanding RF applications, such as video RF, where its internal termination feature is crucial for preventing high-control reflections that could potentially damage the source. This module is engineered to deliver low insertion loss and optimized voltage standing wave ratio (VSWR) to ensure minimal signal degradation, while offering high isolation levels for improved signal integrity.
Equipped with onboard relay count tracking, the PXI-2555 allows users to predict the lifetime of the relays, thereby reducing the likelihood of unexpected system downtime. The module’s control logic facilitates the opening and closing of relays and can handle scan lists of up to 1024 instructions, which are stored in the onboard memory to enable the fastest scans without controller intervention.
Users can configure the PXI-2555 for either single scans or continuous looping through the scan list, with the added benefit of an external trigger input that offers greater flexibility in scan operation by allowing advancement between scan setups. This input is compatible with TTL voltage levels and is edge sensitive, enhancing the module’s adaptability to a variety of triggering scenarios.
Question 1: What are the benefits of using the National Instruments PXI-2555’s onboard relay count tracking in terms of system maintenance and reliability?
Answer 1: The benefits of using the National Instruments PXI-2555’s onboard relay count tracking include the ability to predict the lifetime of the relays, which helps in planning maintenance schedules proactively and reduces the likelihood of unexpected system downtime, thus enhancing overall system reliability and maintenance efficiency.
Question 2: What are the features and benefits of the National Instruments PXI-2555 RF Multiplexer Switch Module designed for video RF applications?
Answer 2: The National Instruments PXI-2555 RF Multiplexer Switch Module offers features such as internal termination to prevent control reflections, low insertion loss, and optimized VSWR for minimal signal degradation, high isolation for improved signal integrity, onboard relay count tracking to predict relay life, the ability to handle scan lists of up to 1024 instructions for quick scans without controller intervention, configurable single or continuous loop scans, and an external TTL-compatible trigger input for flexible scan operation, all of which contribute to its suitability
Question 3: What are the key features and benefits of the National Instruments PXI-2555 RF Multiplexer Switch Module, as detailed in its description?
Answer 3: The National Instruments PXI-2555 RF Multiplexer Switch Module is suitable for video RF applications due to its internal termination feature that prevents high-power reflections that could damage the source, low insertion loss, optimized VSWR for minimal signal degradation, and high isolation levels for improved signal integrity; to minimize unexpected system downtime, it includes onboard relay count tracking to predict relay life, control logic for managing up to 1024 scan instructions, and the flexibility of single or continuous scan configurations with an external TTL
Question 4: What are the key features of the National Instruments PXI-2555 RF Multiplexer Switch Module that make it suitable for video RF applications and minimize unexpected system downtime?
Answer 4: The National Instruments PXI-2555 RF Multiplexer Switch Module is suitable for high-demand RF applications due to its internal termination feature that prevents control reflections, low insertion loss, optimized VSWR for minimal signal degradation, high isolation levels for signal integrity, onboard relay count tracking for predicting relay life, control logic for managing up to 1024 scan instructions, and an external trigger input compatible with TTL voltage levels for flexible scan operations.
Question 5: What are the key features of the National Instruments PXI-2555 RF Multiplexer Switch Module that make it suitable for high-demand RF applications?
Answer 5: The National Instruments PXI-2555 RF Multiplexer Switch Module features low insertion loss and optimized VSWR for minimal signal degradation, high isolation levels for improved signal integrity, internal termination to prevent high-voltage reflections, onboard relay count tracking to predict relay life and reduce system downtime, control logic that can manage up to 1024 instruction scan lists stored in onboard memory for fast scans without controller intervention, configurable options for single scans or continuous looping, and an external TTL-compatible trigger input for flexible scan
Specification | Detail |
---|---|
Manufacturer | National Instruments |
Part Number | 778572-55 |
Product Model | PXI-2555 |
Type | PXI RF Multiplexer Switch Module |
Internal Termination | Yes (prevents high-control reflections) |
Applications | Suitable for video RF applications |
Insertion Loss | Low |
Voltage Standing Wave Ratio (VSWR) | Optimized |
Isolation | High, to limit signal degradation |
Relay Count Tracking | Available (for predicting relay lifetime) |
Control Logic | Onboard, for opening and closing relays |
Maximum Scan List Size | 1024 instructions |
Scan List Memory | Onboard, for fastest possible scans |
Scan Execution | Single or continuous looping |
External Trigger Input | Yes, for advancing between scan setups |
Trigger Compatibility | TTL voltage levels, edge sensitive |