Description
The National Instruments PXI-4070 PXI Digital Multimeter, with part number 778274-01, is a high-precision 6.5 Digit FlexDMM offering a sampling rate of up to 1.8 MS/s. It features a fully isolated, high-voltage digitizer capability and provides a variable resolution range from 10 to 23 bits, allowing for flexibility in measurement accuracy and speed.
Compatible with the NI-DMM driver, this digital multimeter supports a variety of programming languages, including C/C++, .NET, Visual Basic, LabVIEW, and LabWindows/CVI, ensuring seamless integration with existing systems. The DC system specifications include a range/function change of 100/s, an auto range time of 50 ms, a trigger latency of 2 μs, and a maximum trigger rate of 6kHz. Additionally, the AC system boasts a range/function change of 10/s, an auto range time of 250 ms, and a trigger latency measured in microseconds, which are critical for precise and responsive measurements.
Feature | Specification |
---|---|
Part Number | 778274-01 |
Product Type | National Instruments PXI-4070 PXI Digital Multimeter |
Digits of Resolution | 6.5 Digit FlexDMM |
Sampling Rate | Up to 1.8 MS/s |
Digitizer Capability | Fully isolated, high-voltage |
Resolution Range | 10 to 23 bits |
Driver Compatibility | NI-DMM |
Programming Language Compatibility | C/C++, .NET, Visual Basic, LabVIEW, LabWindows/CVI |
DC System – Range/Function Change | 100/s |
DC System – Auto Range Time | 50 ms |
DC System – Trigger Latency | 2 μs |
DC System – Max Trigger Rate | 6kHz |
AC System – Range/Function Change | 10/s |
AC System – Auto Range Time | 250 ms |
AC System – Trigger Latency | μs |
Question 1: What is the maximum sampling rate of the National Instruments PXI-4070 PXI Digital Multimeter, and what resolution range does its FlexDMM offer?
Answer 1: The National Instruments PXI-4070 PXI Digital Multimeter has a maximum sampling rate of 1.8 MS/s and offers a FlexDMM resolution range from 10 to 23 bits.
Question 2: What is the variable resolution range of the National Instruments PXI-4070 PXI Digital Multimeter, and what programming languages does it support?
Answer 2: The National Instruments PXI-4070 PXI Digital Multimeter offers a sampling rate of up to 1.8 MS/s and features a fully isolated, high-voltage digitizer; the NI-DMM driver supports programming languages such as C/C++, .NET, Visual Basic, LabVIEW, and LabWindows/CVI.
Question 3: What programming languages does the National Instruments PXI-4070 PXI Digital Multimeter support for seamless integration with existing systems?
Answer 3: The National Instruments PXI-4070 PXI Digital Multimeter supports a variety of programming languages for seamless integration into existing systems, including C/C++, .NET, Visual Basic, LabVIEW, and LabWindows/CVI.
Question 4: What programming languages are supported by the National Instruments PXI-4070 PXI Digital Multimeter for seamless integration into existing systems?
Answer 4: The variable resolution range of the National Instruments PXI-4070 PXI Digital Multimeter is 10 to 23 bits, and it supports programming languages such as C/C++, .NET, Visual Basic, LabVIEW, and LabWindows/CVI.
Question 5: What is the sampling rate and voltage digitizer isolation capability of the National Instruments PXI-4070 PXI Digital Multimeter, and which programming languages are supported by the NI-DMM driver?
Answer 5: The National Instruments PXI-4070 PXI Digital Multimeter supports C/C++, .NET, Visual Basic, LabVIEW, and LabWindows/CVI programming languages for seamless integration with existing systems.