Description
The National Instruments PXI-4130, with part numbers 779647-30 and 779647-31, is a versatile single slot, 3U PXI module capable of delivering a four-quadrant output voltage of ±20 V. It is designed to provide a high power output, offering up to 40 W in quadrants I and III and up to 10 W in quadrants II and IV, ensuring robust performance for a variety of applications.
Notably, the PXI-4130 features exceptional current measurement resolution down to 1 nA, allowing for precise measurements critical in semiconductor testing and other high-precision tasks. It also includes a utility channel that can output up to 6 V and 1 A, which serves as a complementary power source to the main SMU channel.
Enhanced measurement accuracy is achieved through the support of remote sense on the SMU channel. Software compatibility is broad, encompassing the NI-DCPower driver, LabVIEW, and LabWindows/CVI, facilitating seamless integration into existing systems.
Before operation, it is recommended to allow a warm-up time of 30 minutes for the PXI-4130, and to maintain its precision, calibration is recommended annually or every two years. The device is lightweight at 11 oz and has compact physical dimensions of 8.5 x 5.1 x 0.8 inches, allowing for easy integration into PXI racks without occupying excessive space.
The PXI-4130 is engineered to operate reliably within a temperature range of 0 °C to 55 °C and can be safely stored in temperatures ranging from -40 °C to 70 °C, ensuring durability and longevity under a wide range of environmental conditions.
Question 1: What are the two part numbers associated with the National Instruments PXI-4130, and what are its main characteristics in terms of power output capability, measurement resolution, and additional features?
Answer 1: The recommended warm-up time for the National Instruments PXI-4130 module before operation is 30 minutes, and to maintain its precision, calibration is advised annually or every two years.
Question 2: What are the specific calibration recommendations for the National Instruments PXI-4130 module in terms of frequency to maintain its precision?
Answer 2: To maintain its precision, it is recommended that the National Instruments PXI-4130 module be calibrated annually or every two years.
Question 3: What are the output power capabilities of the National Instruments PXI-4130 in the different quadrants, and what is its current measurement resolution?
Answer 3: The National Instruments PXI-4130 has a minimum current measurement resolution of 1 nA, and to maintain its precision, it is recommended to calibrate the device annually or every two years.
Question 4: What is the minimum current measurement resolution of the National Instruments PXI-4130, and what are the recommended calibration intervals to maintain its precision?
Answer 4: The National Instruments PXI-4130 is capable of delivering up to 40 W of power output in quadrants I and III, and up to 10 W in quadrants II and IV, with an exceptional current measurement resolution of down to 1 nA.
Question 5: What is the recommended warm-up time for the National Instruments PXI-4130 module before it is operated, and how often is calibration advised to maintain its precision?
Answer 5: The National Instruments PXI-4130 has the part numbers 779647-30 and 779647-31, and it is characterized by its power output capability of up to 40 W in quadrants I and III, and up to 10 W in quadrants II and IV, with a voltage output of ±20 V. It offers exceptional measurement resolution down to 1 nA, and includes additional features such as a utility channel with up to 6 V and 1 A output
Specification | Details |
---|---|
Part Numbers | 779647-30, 779647-31 |
Form Factor | Single slot, 3U PXI module |
Output Voltage | ±20 V (four-quadrant) |
Power Output | Up to 40 W in quadrants I and III, Up to 10 W in quadrants II and IV |
Current Measurement Resolution | Down to 1 nA |
Utility Channel Output | Up to 6 V and 1 A |
Remote Sense | Supported on SMU channel |
Software Compatibility | NI-DCPower driver, LabVIEW, LabWindows/CVI |
Warm-up Time | 30 minutes |
Calibration Frequency | Annually or every two years recommended |
Weight | 11 oz |
Physical Dimensions | 8.5 x 5.1 x 0.8 inches |
Operating Temperature Range | 0 °C to 55 °C |
Storage Temperature Range | -40 °C to 70 °C |