Description
The National Instruments PXI-4132 PXI Source Measure Unit, with Part Numbers 780558-01 and 190463E-01L, boasts a precise measurement resolution of 10 pA and an expansive output voltage range of ±100 V.
Its sophisticated output configuration is designed as a four-quadrant system, complete with integrated external guarding and 4-wire sensing capabilities for enhanced accuracy.
The unit can achieve a remarkable maximum source update rate of 4,200 updates/s, with a minimal trigger into source delay of only 500 ns, utilizing PXI Trigger Lines <0…7> for flexible control.
It can generate multiple output triggers, including source complete, sequence engine done, sequence iteration complete, and measure complete events, to facilitate complex testing sequences.
Designed as a 3U one-slot PXI module, it has nominal dimensions of 2.0 cm × 13.0 cm × 21.6 cm and weighs approximately 295 g, making it compact and suitable for integration into a variety of test systems.
The module is equipped with 8 position, 5.08 mm COMBICON front panel connectors, ensuring reliable and secure connections for test leads and accessories.
Specification | Detail |
---|---|
Part Number | 780558-01, 190463E-01L |
Product | National Instruments PXI-4132 PXI Source Measure Unit |
Measurement Resolution | 10 pA |
Output Voltage Range | ±100 V |
Output Configuration | Four-quadrant |
External Guarding | Integrated |
Sensing | 4-wire sense |
Maximum Source Update Rate | 4,200 updates/s |
Trigger into Source Delay | 500 ns |
PXI Trigger Lines | <0…7> |
Output Triggers (Events) | Source complete, sequence engine done, sequence iteration complete, measure complete |
Form Factor | 3U, one-slot, PXI module |
Dimensions (W×H×D) | 2.0 cm × 13.0 cm × 21.6 cm |
Weight | Approx. 295 g |
Front Panel Connectors | 8 position, 5.08 mm COMBICON
Question 1: What features of the National Instruments PXI-4132 PXI Source Measure Unit allow it to deliver enhanced accuracy in its measurements? Answer 1: The National Instruments PXI-4132 PXI Source Measure Unit offers a precise current measurement resolution of 10 pA and has a maximum output voltage range of ±100 V. Question 2: What is the maximum source update rate of the National Instruments PXI-4132 PXI Source Measure Unit, and what are its part numbers? Question 3: What is the measurement resolution and output voltage range of the National Instruments PXI-4132 PXI Source Measure Unit? Question 4: What is the maximum source update rate of the National Instruments PXI-4132 PXI Source Measure Unit, and what is its trigger into source delay time? Question 5: What is the precision of the current measurement resolution offered by the National Instruments PXI-4132 PXI Source Measure Unit, and what is its maximum output voltage range? |