img

PXI-4465

The National Instruments PXI-4465 Dynamic Signal Analyzer is a highly accurate sound and vibration analysis tool with 2 analog input channels, 204.8 kS/s sampling rate, and a dynamic range of 118 dB, suitable for a wide

In Stock | Ships Today

img

    Description

    The National Instruments PXI-4465 Dynamic Signal Analyzer is designed for a variety of sound and vibration applications, such as laboratory research, audio testing, automotive testing, noise and vibration diagnostics, and NVH assessment. It features two high-precision analog input channels that provide a maximum sample rate of 204.8 kS/s and employ 24-bit Delta-sigma ADCs to achieve a dynamic range of 118 dB.

    This analyzer offers six gain settings to accommodate input ranges from ±316 mV to ±42.4 V, giving users the versatility to handle various signal types. The device supports software-configurable AC/DC coupling and IEPE conditioning, along with variable antialiasing filters to ensure high-quality measurements.

    Connectivity is provided through BNC female analog I/O connectors and an SMB male digital trigger connector, ensuring easy integration with a wide range of devices. The PXI-4465 is also compatible with the MXI platform and occupies a single slot in the chassis, with an excitation current of 10 mA, making it a compact and efficient solution for data acquisition and analysis.

    Question 1: What are the capabilities and features of the National Instruments PXI-4465 Dynamic Signal Analyzer that make it suitable for sound and vibration applications?
    Answer 1: The National Instruments PXI-4465 Dynamic Signal Analyzer can be utilized in automotive testing environments for tasks such as engine vibration analysis, vehicle cabin noise measurements, audio system quality assessment, exhaust system diagnostics, and evaluating the performance of vibration isolation components to ensure vehicle NVH (Noise, Vibration, and Harshness) standards are met.

    Question 2: How does the National Instruments PXI-4465 Dynamic Signal Analyzer accommodate various signal types in sound and vibration applications?
    Answer 2: The National Instruments PXI-4465 Dynamic Signal Analyzer is equipped for diverse sound and vibration tasks with two high-precision analog input channels, a maximum sample rate of 204.8 kS/s, 24-bit Delta-sigma ADCs for a dynamic range of 118 dB, six gain settings ranging from ±316 mV to ±42.4 V, software-configurable AC/DC coupling and IEPE conditioning, variable antialiasing filters, BNC female analog I/O connectors,

    Question 3: Considering the specifications and features described, what are some potential use cases for the National Instruments PXI-4465 Dynamic Signal Analyzer in automotive testing environments?
    Answer 3: The National Instruments PXI-4465 Dynamic Signal Analyzer is designed for applications such as laboratory research, audio testing, automotive testing, noise and vibration diagnostics, and NVH (noise, vibration, and harshness) assessment; it supports these applications with features like two high-precision analog input channels with a maximum sample rate of 204.8 kS/s, 24-bit Delta-sigma ADCs for a dynamic range of 118 dB, six gain settings to handle input ranges from ±316

    Question 4: What applications is the National Instruments PXI-4465 Dynamic Signal Analyzer designed for, and what features does it have to support these applications?
    Answer 4: The National Instruments PXI-4465 Dynamic Signal Analyzer is well-suited for sound and vibration applications due to its two high-precision analog input channels with a 204.8 kS/s maximum sample rate, 24-bit Delta-sigma ADCs for a dynamic range of 118 dB, six gain settings to handle input ranges from ±316 mV to ±42.4 V, software-configurable AC/DC coupling and IEPE conditioning, variable antialiasing filters for high-quality measurements

    Question 5: What are the specifications and capabilities of the National Instruments PXI-4465 Dynamic Signal Analyzer for handling various sound and vibration applications?
    Answer 5: The National Instruments PXI-4465 Dynamic Signal Analyzer accommodates various signal types in sound and vibration applications through its six gain settings for input ranges from ±316 mV to ±42.4 V, software-configurable AC/DC coupling, IEPE conditioning, and variable antialiasing filters to ensure high-quality measurements.

    Feature Description
    Product Name National Instruments PXI-4465 Dynamic Signal Analyzer
    Manufacturer National Instruments
    Application Sound and vibration applications including laboratory research, audio test, automotive test, noise/vibration diagnostics, NVH assessment, etc.
    Number of Channels 2 analog input channels
    Maximum Sample Rate 204.8 kS/s
    ADC Type 24-bit, Delta-sigma ADCs
    Dynamic Range 118 dB
    Gain Settings 6 settings, input ranges from ±316 mV to ±42.4 V
    Coupling Software-configurable AC/DC
    IEPE Conditioning Supported
    Antialiasing Filters Variable
    Analog I/O Connectors BNC female
    Digital Trigger Connector SMB male
    Compatibility MXI platform
    Module Width 1 slot
    Excitation Current 10 mA