img

PXI-5112

The National Instruments PXI-5112 PXI Digitizer features two analog input channels with a signal input range of ±0.025 V to ±25 V, 8-bit ADC resolution, and a sampling rate of 100 MS/s to

In Stock | Ships Today

img

    Description

    The National Instruments PXI-5112 PXI Digitizer is a sophisticated measurement device that features two analog input channels with a signal input range adjustable from ±0.025 V to ±25 V in 10 percent increments, and it comes in two distinct part numbers: 777758-01 with 16 MB per channel and 777756-01 with 32 MB per channel.

    Each channel on the PXI-5112 can leverage a programmable DC offset, which can be set up to 20 times the input range based on the selected range. Additionally, the device offers AC coupling and a hardware bandwidth limit of 20 MHz per channel, allowing for versatile signal processing capabilities.

    It incorporates the NI-TIO ASIC, a specialized counter and timing I/O ASIC, that delivers precise timing with 2 ns precision for real-time sampling and 100 ps precision for random-interleaved sampling (RIS).

    The PXI-5112’s analog-to-digital conversion is carried out with an 8-bit ADC resolution, and it supports a wide range of sampling rates from 100 MS/s to 1 S/s, with the capability to sample repetitive signals at up to 2.5 GS/s. Connectivity options include 2 BNC female, 1 SMB female, and a 9-pin DIN I/O connector.

    With physical dimensions of 3.9 x 6.3 inches, the PXI-5112 is designed to fit into compact spaces while providing robust performance in a recommended operating temperature range that commences at 0 °C.

    Question 1: What are the key features and specifications of the National Instruments PXI-5112 PXI Digitizer, including its analog input channels, range capabilities, part numbers with respective memory sizes, and analog-to-digital conversion performance?
    Answer 1: The National Instruments PXI-5112 PXI Digitizer is available in two distinct memory capacity options: part number 777758-01 with 16 MB per channel and part number 777756-01 with 32 MB per channel, which affect the device’s data storage capabilities by determining the amount of data each channel can store during acquisition.

    Question 2: What are the differences in memory capacity between the two part numbers of the National Instruments PXI-5112 PXI Digitizer, and what are the adjustable signal input range and DC offset capabilities of this device?
    Answer 2: The National Instruments PXI-5112 PXI Digitizer part number 777758-01 has 16 MB of memory per channel, while part number 777756-01 has 32 MB of memory per channel; the device features an adjustable signal input range from ±0.025 V to ±25 V in 10 percent increments and a programmable DC offset up to 20 times the selected input range.

    Question 3: What are the differences in memory capacity between the two part numbers of the National Instruments PXI-5112 PXI Digitizer, and what specific features enhance its signal processing and timing capabilities?
    Answer 3: The National Instruments PXI-5112 PXI Digitizer comes in two versions: part number 777758-01 with 16 MB of memory per channel and part number 777756-01 with 32 MB of memory per channel; its signal processing is enhanced by features such as programmable DC offset, AC coupling, and a hardware bandwidth limit of 20 MHz per channel, while its timing capabilities are bolstered by the NI-TIO ASIC, which provides precise timing with 2 ns

    Question 4: What are the distinct memory capacity options available for the National Instruments PXI-5112 PXI Digitizer, and how do they affect the device’s data storage capabilities?
    Answer 4: The National Instruments PXI-5112 PXI Digitizer boasts two analog input channels with an adjustable range from ±0.025 V to ±25 V in 10 percent increments and comes in two versions: part number 777758-01 with 16 MB per channel and part number 777756-01 with 32 MB per channel. It features a programmable DC offset up to 20 times the input range, AC coupling, a 20 MHz hardware bandwidth limit per channel, and

    Question 5: What is the range of input signal voltages that can be adjusted for the National Instruments PXI-5112 PXI Digitizer, and what are the part numbers corresponding to its two memory capacity options?
    Answer 5: The input signal voltage range for the National Instruments PXI-5112 PXI Digitizer can be adjusted from ±0.025 V to ±25 V in 10 percent increments, and the two part numbers corresponding to its memory capacity options are 777758-01 with 16 MB per channel and 777756-01 with 32 MB per channel.

    Feature Specification
    Product National Instruments PXI-5112 PXI Digitizer
    Part Numbers 777758-01 (16 MB/channel), 777756-01 (32 MB/channel)
    Analog Input Channels 2
    Signal Input Range ±0.025 V to ±25 V, variable in 10 percent steps
    Programmable DC Offset Up to 20 times the input range, depending on the range selected
    AC Coupling Available
    Hardware Bandwidth Limit 20 MHz per channel
    NI-TIO ASIC For counter and timing I/O
    Timing Precision 2 ns for real-time sampling, 100 ps for RIS
    ADC Resolution 8-bit
    Sampling Rates 100 MS/s to 1 S/s, up to 2.5 GS/s for repetitive signals
    Connectors 2 BNC female, 1 SMB female, 9-pin DIN I/O
    Physical Dimensions 3.9 x 6.3 in.
    Operating Temperature 0 °C