The National Instruments PXI-5900 is a differential PXI amplifier with a part number of 780166-01, featuring two input channels, software-selectable input impedance, and compatibility with the PXI-5922 oscilloscope module and
The National Instruments PXI-5900 is a PXI Differential Amplifier with Part Number 780166-01, explicitly designed to work with the PXI-5922 oscilloscope module. This versatile amplifier features two input channels that offer GND, AC, and DC coupling capabilities along with a software-selectable input impedance of 50 Ω ±2%. The input connectors are BNC for input and SMB for output, ensuring compatibility with a variety of test setups.
With a vertical gain accuracy of 0.25 ±0.2% and a zero input offset error of 500 μV, the PXI-5900 delivers precise measurements. Its passband flatness is within 1 dB, and it offers an impressive common-mode rejection ratio of 70 dB at 60 Hz, which is crucial for reducing noise in measurement systems. The device’s slew rate stands at 100 V/μs when referred to balanced differential input, providing fast response times for dynamic signals.
Designed for ease of use and integration, the PXI-5900 is compatible with NI-SCOPE 3.5.1, an IVI-compliant driver that facilitates the control, configuration, and calibration of the amplifier. Additionally, it can be managed using the NI Measurement & Automation Explorer (MAX) software tools, which offer interactive configuration and testing features. This comprehensive toolset makes the PXI-5900 an essential component for engineers looking for a reliable and precise amplifier solution in their PXI systems.
Feature
Specification
Manufacturer
National Instruments
Model
PXI-5900
Part Number
780166-01
Type
PXI Differential Amplifier
Compatible With
PXI-5922
Input Channels
2 with GND, AC, and DC coupling
Input Impedance
50 Ω ±2% (software-selectable)
Input Connectors
BNC (input), SMB (output)
Vertical Gain Accuracy
0.25 ±0.2%
Zero Input Offset Error
500 μV
Passband Flatness
1 dB
Common-Mode Rejection Ratio
70 dB at 60 Hz
Slew Rate
100 V/μs (differential input)
Driver Compatibility
NI-SCOPE 3.5.1
Software Tools
NI Measurement & Automation Explorer (MAX)
Question 1: What are the key features and compatibility options of the National Instruments PXI-5900 Differential Amplifier, including its input impedance, gain accuracy, passband flatness, and software support? Answer 1: The National Instruments PXI-5900 features a software-selectable input impedance of 50 Ω ±2% and uses BNC connectors for input and SMB for output, which contribute to its compatibility with various test setups by allowing for easy integration with a wide range of cabling and instrumentation commonly used in testing environments.
Question 2: What are the main features and specifications of the National Instruments PXI-5900 Differential Amplifier designed to pair with the PXI-5922 oscilloscope module? Answer 2: The National Instruments PXI-5900 Differential Amplifier, designed to pair with the PXI-5922 oscilloscope module, features two input channels with GND, AC, and DC coupling options, a software-selectable input impedance of 50 Ω ±2%, BNC input and SMB output connectors, a vertical gain accuracy of 0.25 ±0.2%, a zero input offset error of 500 µV, passband flatness within 1 dB, a common
Question 3: What are the key features and capabilities of the National Instruments PXI-5900 Differential Amplifier when used with the PXI-5922 oscilloscope module? Answer 3: The National Instruments PXI-5900 Differential Amplifier boasts key features such as two input channels with GND, AC, and DC coupling capabilities, a software-selectable input impedance of 50 Ω ±2%, a vertical gain accuracy of 0.25 ±0.2%, and a passband flatness within 1 dB, complemented by compatibility options that include input connectors (BNC for input and SMB for output), and software support through integration with NI-SCOPE 3
Question 4: What are the key specifications and compatibility features of the National Instruments PXI-5900 PXI Differential Amplifier, Part Number 780166-01, when used together with the PXI-5922 oscilloscope module? Answer 4: The National Instruments PXI-5900 Differential Amplifier, when used with the PXI-5922 oscilloscope module, boasts key features such as two input channels with ground, AC, and DC coupling options, software-selectable input impedance of 50 Ohms ±2%, BNC input and SMB output connectors, vertical gain accuracy of 0.25 ±0.2%, a zero input offset error of 500 µV, passband flatness within 1 dB, a common
Question 5: What are the impedance and input connector types of the National Instruments PXI-5900, and how do they contribute to its compatibility with various test setups? Answer 5: The National Instruments PXI-5900 PXI Differential Amplifier, Part Number 780166-01, when paired with the PXI-5922 oscilloscope module, offers two input channels with GND, AC, and DC coupling capabilities, a software-selectable input impedance of 50 Ω ±2%, BNC input and SMB output connectors, a vertical gain accuracy of 0.25 ±0.2%, a zero input offset error of 500 µV, passband