Description
The National Instruments PXI-6289 PXI Multifunction I/O Module is a versatile device designed to provide a comprehensive solution for data acquisition and control with its 18-Bit resolution and a maximum sample rate of 625 kS/s for single-channel operations and 500 kS/s when operating in multichannel mode. It integrates 4 analog outputs (AO) and 48 digital I/O (DIO), alongside 32 analog inputs (AI) that can be configured as either 16 differential or 32 single-ended channels to cater to a broad range of application requirements.
The module is equipped with two 32-bit counter/timers and supports both analog and digital triggering, enhancing its flexibility in various experimental and industrial setups. It offers two specific part numbers, namely 779639-01, which comes with a PXI hybrid bus connector, and 779123-01, which features a PXI bus connector, allowing for integration with different system architectures.
For optimal performance, a 15-minute warm-up time is recommended, and to maintain accuracy, calibration is advised at least once every two years. The module boasts a timing resolution of 50 ns and a timing accuracy of 50 ppm. It also ensures signal integrity with an input impedance of >10 GΩ for both AI+ to AI GND and AI- to AI GND, in parallel with 100 pF.
Question 1: What are the key features and specifications of the National Instruments PXI-6289 PXI Multifunction I/O Module regarding resolution, sample rates, I/O capabilities, triggering options, part numbers, and performance recommendations?
Answer 1: The National Instruments PXI-6289 PXI Multifunction I/O Module is available in two configurations: part number 779639-01 with a PXI hybrid bus connector and part number 779123-01 with a PXI bus connector; for optimal performance, a warm-up time of 15 minutes is recommended, and calibration should be conducted at least once every two years.
Question 2: What is the recommended warm-up time for optimal performance of the National Instruments PXI-6289 PXI Multifunction I/O Module, and how often is calibration advised to maintain its accuracy?
Answer 2: The National Instruments PXI-6289 PXI Multifunction I/O Module features an 18-Bit resolution, with maximum sample rates of 625 kS/s for single-channel and 500 kS/s for multichannel operations, includes 4 analog outputs, 48 digital I/Os, and 32 analog inputs configurable as 16 differential or 32 single-ended channels, offers two 32-bit counter/timers, supports analog and digital triggering, comes in part numbers 779
Question 3: What are the specifications and features of the National Instruments PXI-6289 PXI Multifunction I/O Module, including its resolution, sample rates, number of analog and digital channels, and counter/timer capabilities?
Answer 3: The recommended warm-up time for optimal performance of the National Instruments PXI-6289 PXI Multifunction I/O Module is 15 minutes, and it is advised to calibrate the module at least once every two years to maintain its accuracy.
Question 4: What are the distinctive features and capabilities of the National Instruments PXI-6289 PXI Multifunction I/O Module, including its resolution, sample rates, and analog and digital input/output specifications?
Answer 4: The National Instruments PXI-6289 PXI Multifunction I/O Module features an 18-Bit resolution, offers a maximum sample rate of 625 kS/s for single-channel operations and 500 kS/s in multichannel mode, includes 4 analog outputs and 48 digital I/O channels, and provides 32 analog inputs which can be configured as either 16 differential or 32 single-ended channels, along with two 32-bit counter/timers for extensive data acquisition and
Question 5: What are the configurations and part numbers available for the National Instruments PXI-6289 PXI Multifunction I/O Module, and what is the recommended warm-up time and calibration frequency for optimal performance?
Answer 5: The National Instruments PXI-6289 PXI Multifunction I/O Module offers a range of distinctive features, including an 18-Bit resolution, a maximum sample rate of 625 kS/s for single-channel and 500 kS/s for multi-channel operations, 4 analog outputs, 48 digital I/Os, 32 analog inputs configurable as 16 differential or 32 single-ended channels, two 32-bit counter/timers, analog and digital triggering capabilities, and superior signal
Feature | Specification |
---|---|
Product Type | National Instruments PXI-6289 PXI Multifunction I/O Module |
Analog Outputs (AO) | 4 |
Digital I/O (DIO) | 48 |
Analog Inputs (AI) | 32 (16 differential or 32 single-ended channels) |
Resolution | 18-Bit |
Maximum Sample Rate | 625 kS/s (single-channel), 500 kS/s (multichannel) |
Counter/Timers | Two 32-bit |
Triggering | Analog, Digital |
Part Numbers | 779639-01 (PXI hybrid bus connector), 779123-01 (PXI bus connector) |
Warm-up Time | 15 minutes recommended |
Calibration Interval | At least once every 2 years |
Timing Resolution | 50 ns |
Timing Accuracy | 50 ppm |
Input Impedance | >10 GΩ (AI+ to AI GND, AI- to AI GND) in parallel with 100 pF |