The National Instruments PXI-6514 is a 64-channel isolated digital I/O module with a ±30 VDC voltage range, entirely software configurable without jumpers, featuring programmable power-up states, digital filtering, NI digital I/O watchdog technology
The National Instruments PXI-6514 PXI Digital I/O Module, with part number 778965-01, is a versatile and robust data acquisition device offering a 64-channel configuration that includes 32 digital inputs (DI) and 32 digital outputs (DO). This module operates within a voltage range of ±30 VDC and is isolated to protect against electrical interference.
Input logic levels are clearly defined with a high logic level ranging from 11 to 30 V and a low logic level being 4 V or less, ensuring reliable signal processing. The PXI-6514 is entirely software configurable, eliminating the need for manual jumper settings and streamlining setup and changes.
Programmable power-up states can be set for safety and control in automated environments. With built-in digital filtering, the module is adept at reducing signal noise and avoiding false triggering. The inclusion of NI’s digital I/O watchdog technology provides a safeguard against system malfunctions, such as crashes or unresponsive applications.
Change detection capability allows for efficient monitoring, as the module can trigger a notification or action upon detecting a change in state. Compatibility with NIDAQmx driver software and integration with development platforms like LabVIEW and LabWindows/CVI make this module a flexible choice for engineers and developers.
Connection to the module is made simple with a 100-pin high-density SCSI connector, and various cable and connector block options, including the R1005050 ribbon cable and CB-50 or CB-50LP Connector Blocks for unshielded connectivity, or the SH100-100-F Shielded Digital I/O Cable and the CB-37FH DIN-rail-mountable Connector Block for shielded setups. Despite its extensive capabilities, the PXI-6514 maintains a compact form factor with a weight of just 6.1 oz.
Specification
Detail
Product Name
National Instruments PXI-6514 PXI Digital I/O Module
Part Number
778965-01
Channel Count
64-Channel (32 DI, 32 DO)
Voltage Range
±30 VDC, Isolated
Input Logic Level
High: 11 to 30 V; Low: 4 V or less
Software Configuration
Entirely software configurable, no jumpers needed
Programmable Power-Up States
Yes
Digital Filtering
Yes
Watchdog Technology
NI digital I/O watchdog
Change Detection
Yes
Driver Software
NIDAQmx, compatible with LabVIEW, LabWindows/CVI
Connector Type
100-pin high-density SCSI
Compatible Cables & Connector Blocks
R1005050 ribbon cable, CB-50 or CB-50LP Connector Blocks, SH100-100-F Shielded Digital I/O Cable, CB-37FH DIN-rail-mountable Connector Block
Weight
6.1 oz
Question 1: What are the key features and compatibilities of the National Instruments PXI-6514 PXI Digital I/O Module, part number 778965-01, that make it suitable for automated environments and noise reduction in signal processing? Answer 1: The built-in digital filtering of the National Instruments PXI-6514 PXI Digital I/O Module helps to reduce signal noise and prevent false triggering, enhancing the reliability of signal processing, while NI’s digital I/O watchdog technology offers a safeguard against system malfunctions by monitoring the system’s responsiveness and acting accordingly to maintain operational integrity.
Question 2: What features and specifications make the National Instruments PXI-6514 PXI Digital I/O Module, part number 778965-01, an effective choice for data acquisition and signal processing in automated environments? Answer 2: The National Instruments PXI-6514 PXI Digital I/O Module, part number 778965-01, is designed for automated environments and noise reduction in signal processing with its key features including a 64-channel configuration with 32 inputs and 32 outputs, voltage isolation, software configurability, programmable power-up states, built-in digital filtering, NI’s digital I/O watchdog technology, and change detection capability. Furthermore, its compatibility with NIDAQmx driver software, LabVIEW, and
Question 3: What features and capabilities does the National Instruments PXI-6514 PXI Digital I/O Module offer for signal processing and system integration? Answer 3: The National Instruments PXI-6514 PXI Digital I/O Module offers a 64-channel configuration with 32 digital inputs and 32 digital outputs, operates within a ±30 VDC voltage range, features input logic levels for reliable signal processing, is software configurable, includes programmable power-up states, built-in digital filtering to reduce signal noise, NI’s digital I/O watchdog technology for system protection, change detection for efficient monitoring, compatibility with NIDAQmx driver software, integration with LabVIEW
Question 4: What are the benefits of the National Instruments PXI-6514 PXI Digital I/O Module’s built-in digital filtering and NI’s digital I/O watchdog technology? Answer 4: The National Instruments PXI-6514 PXI Digital I/O Module, part number 778965-01, is an effective choice for data acquisition and signal processing in automated environments due to its 64-channel configuration with equal numbers of digital inputs and outputs, operating voltage range of ±30 VDC with isolation for electrical interference protection, clearly defined input logic levels, software configurability, programmable power-up states for safety, built-in digital filtering to reduce noise, NI’s digital I/O watchdog technology
Question 5: What is the function of NI’s digital I/O watchdog technology in the National Instruments PXI-6514 PXI Digital I/O Module, and how does it contribute to system reliability? Answer 5: NI’s digital I/O watchdog technology in the National Instruments PXI-6514 PXI Digital I/O Module serves as a protective feature that monitors the system’s operation for malfunctions, such as crashes or unresponsive applications, and can take predefined actions to maintain system safety and reliability. This contributes to system reliability by ensuring that the digital I/O module can recover from faults or maintain a safe state, thus preventing damage to the system or process being controlled.