Description
The National Instruments PXI-6723 PXI Analog Output Module, with part number 778998-01, outputs analog voltage and integrates easily into systems using technologies such as the RTSI bus, PXI trigger bus, and PFI pins. This module is equipped with two 68-pin VHDCI connectors and requires 300 mA at +3.3 VDC, up to 3 A at +5 VDC, and 1 A at +4.56 to +5.25 VDC for power.
National Instruments provides Basic and Standard System Assurance Programs to guarantee system integration and performance. The PXI-6723 has a recommended warm-up time of 15 minutes before operation and should be calibrated at least once a year to maintain accuracy.
Physically, it measures 6.3 x 3.9 inches, excluding connectors, and can operate within a temperature range of 0 °C to 50 °C. It should be stored in temperatures ranging from -20 °C to 70 °C and can withstand a noncondensing humidity range of 5% to 90% RH. The module’s channel-to-earth working voltage is rated at ±11 V maximum (CAT I), which helps ensure safe operation within its intended environments.
Question 1: What are the environmental operating conditions and calibration requirements for the National Instruments PXI-6723 PXI Analog Output Module?
Answer 1: The National Instruments PXI-6723 PXI Analog Output Module with part number 778998-01 requires 300 mA at +3.3 VDC, up to 3 A at +5 VDC, and 1 A at +4.56 to +5.25 VDC to operate effectively.
Question 2: What are the electrical power requirements for the National Instruments PXI-6723 PXI Analog Output Module with part number 778998-01?
Answer 2: The National Instruments PXI-6723 PXI Analog Output Module requires 300 mA at +3.3 VDC, up to 3 A at +5 VDC, and 1 A at +4.56 to +5.25 VDC to function properly. It is recommended that the module be allowed a warm-up time of 15 minutes before operation and that it should be calibrated at least once a year to ensure accuracy.
Question 3: What power requirements must be met for the National Instruments PXI-6723 PXI Analog Output Module to operate effectively, considering its part number 778998-01?
Answer 3: The National Instruments PXI-6723 PXI Analog Output Module, with part number 778998-01, requires 300 mA at +3.3 VDC, up to 3 A at +5 VDC, and 1 A at +4.56 to +5.25 VDC for power.
Question 4: What power requirements must be met for the National Instruments PXI-6723 PXI Analog Output Module to function properly, and what are the recommended practices concerning its warm-up time and calibration frequency?
Answer 4: The National Instruments PXI-6723 PXI Analog Output Module operates within a temperature range of 0 °C to 50 °C, can withstand a noncondensing humidity range of 5% to 90% RH, and should be calibrated at least once a year to maintain accuracy.
Question 5: What is the power requirement range for the National Instruments PXI-6723 PXI Analog Output Module, and what are its physical dimensions and operational temperature limits?
Answer 5: The National Instruments PXI-6723 PXI Analog Output Module requires 300 mA at +3.3 VDC, up to 3 A at +5 VDC, and 1 A at +4.56 to +5.25 VDC for power; physically, it measures 6.3 x 3.9 inches, and can operate within a temperature range of 0 °C to 50 °C.
Specification | Details |
---|---|
Product Name | National Instruments PXI-6723 PXI Analog Output Module |
Part Number | 778998-01 |
Output Type | Analog Voltage |
Integration Technologies | RTSI bus, PXI trigger bus, PFI pins |
Connectors | 2 x 68-pin VHDCI |
Power Requirements | 300 mA at +3.3 VDC, 3 A max at +5 VDC, 1 A at +4.56 to +5.25 VDC |
System Assurance Programs | NI Basic and Standard System Assurance |
Recommended Warm-Up Time | 15 minutes |
Calibration Period | At least once a year |
Physical Dimensions | 6.3 x 3.9 in. (excluding connectors) |
Operating Temperature | 0 °C to 50 °C |
Storage Temperature | -20 °C to 70 °C |
Humidity Range | 5% to 90% RH (noncondensing) |
Channel-to-Earth Voltage | ±11 V max (CAT I) |