Description
The National Instruments PXI-7852R R Series module, part number 780340-01, offers a comprehensive range of features including eight analog input channels with DIFF, RSE, and NRSE input modes, 16-bit resolution, and a fast 1 μs conversion time. It provides a high maximum sampling rate of 750 kS/s per channel, alongside eight analog output channels and an extensive 96 digital I/O channels. At its core is the powerful Virtex-5 LX50 FPGA, containing 1,728 kbits of embedded block RAM and 48 DSP48 slices with 25 x 18 multipliers for robust signal processing capabilities.
With dimensions of 6.7 x 4.3 inches and a lightweight design at only 152 grams, the module is compact and portable. The recommended warm-up time is 15 minutes for optimal performance, and it has a suggested calibration interval of one year. Furthermore, it includes a self-calibration feature to ensure accuracy and reliability in measurements.
Question 1: What signal processing capabilities are enabled by the Virtex-5 LX50 FPGA in the National Instruments PXI-7852R R Series module?
Answer 1: The Virtex-5 LX50 FPGA in the National Instruments PXI-7852R R Series module enables robust signal processing capabilities with its 1,728 kbits of embedded block RAM and 48 DSP48 slices, which include 25 x 18 multipliers for advanced signal processing tasks.
Question 2: What are the specifications and features of the National Instruments PXI-7852R R Series module with part number 780340-01 in terms of input channels, resolution, conversion time, and processing capabilities?
Answer 2: The National Instruments PXI-7852R R Series module, part number 780340-01, has a conversion time of 1 μs and a maximum sampling rate of 750 kS/s per channel.
Question 3: What are the input modes available on the National Instruments PXI-7852R R Series module, and what is its maximum sampling rate per channel?
Answer 3: The National Instruments PXI-7852R R Series module, part number 780340-01, has a maximum sampling rate of 750 kS/s per channel and features eight analog input channels.
Question 4: What is the conversion time and maximum sampling rate per channel for the National Instruments PXI-7852R R Series module with part number 780340-01?
Answer 4: The input modes available on the National Instruments PXI-7852R R Series module are DIFF, RSE, and NRSE, and its maximum sampling rate per channel is 750 kS/s.
Question 5: What is the maximum sampling rate and analog input channel count of the National Instruments PXI-7852R R Series module with part number 780340-01?
Answer 5: The National Instruments PXI-7852R R Series module, with part number 780340-01, features eight analog input channels with DIFF, RSE, and NRSE input modes, a 16-bit resolution, a rapid 1 μs conversion time, and robust signal processing capabilities powered by a Virtex-5 LX50 FPGA, which includes 1,728 kbits of embedded block RAM and 48 DSP48 slices with 25 x 18 multipliers.
Feature | Specification |
---|---|
Part Number | 780340-01 |
Product Line | National Instruments PXI-7852R R Series |
Analog Input Channels | 8 |
Input Modes | DIFF, RSE, NRSE |
Resolution | 16 bits |
Conversion Time | 1 μs |
Maximum Sampling Rate | 750 kS/s per channel |
Analog Output Channels | 8 |
Digital I/O Channels | 96 |
FPGA | Virtex-5 LX50 |
Embedded Block RAM | 1,728 kbits |
DSP48 Slices | 48 (25 x 18 multipliers) |
Dimensions | 6.7 x 4.3 inches |
Weight | 152 grams |
Warm-Up Time | 15 minutes |
Calibration Interval | 1 year |
Self-Calibration Feature |