Description
The National Instruments PXI-8511/2 PXI CAN Interface Module, with part number 780686-02, is designed for low-speed/fault-tolerant CAN communication and features two TJA1054A transceivers with a minimum baud rate of 40 kbits/s across its two ports. This module requires one CAN Breakout Box (part number 780041-01) and two 1-meter long, 9-pin D-SUB female NI CAN No Termination Cables (part number 193128-01) for operation. It notably lacks an external sync connector and allows for software-selectable termination options of 1.11 kΩ or 4.99 kΩ, although the nominal impedance of the cable must be 120 Ω as specified by ISO 11898, and each termination resistor must be capable of dissipating 0.25 W of power.
Specification | Detail |
---|---|
Product | National Instruments PXI-8511/2 PXI CAN Interface Module |
Part Number | 780686-02 |
Required Components for Operation | 1 CAN Breakout Box (780041-01), 2 Cables (193128-01) |
Cable Type | 9-pin D-SUB female NI CAN No Termination Cable |
Cable Length | 1 meter |
Module Type | Low-Speed/Fault-Tolerant |
Transceivers | TJA1054A |
Minimum Baud Rate | 40 kbits/s |
Number of Ports | 2 |
External Sync Connector | No |
Software-selectable Termination Options | 1.11 kΩ, 4.99 kΩ |
Nominal Cable Impedance | 120 Ω (as per ISO 11898) |
Termination Resistor Power Dissipation | 0.25 W |
Question 1: What is the minimum baud rate supported by the National Instruments PXI-8511/2 PXI CAN Interface Module, and what specific cable and breakout box part numbers are required for its operation?
Answer 1: The required nominal impedance of the cable for the National Instruments PXI-8511/2 PXI CAN Interface Module to operate correctly is 120 Ohms, as specified by ISO 11898.
Question 2: What is the required nominal impedance of the cable according to ISO 11898 for the National Instruments PXI-8511/2 PXI CAN Interface Module to operate correctly?
Answer 2: The National Instruments PXI-8511/2 PXI CAN Interface Module, part number 780686-02, is designed for low-speed/fault-tolerant CAN communication, featuring two TJA1054A transceivers with a minimum baud rate of 40 kbits/s across two ports, and requires a CAN Breakout Box (part number 780041-01) and two 1-meter long, 9-pin D-SUB female NI CAN No Termination Cables (
Question 3: What are the specifications and required accessories for the National Instruments PXI-8511/2 PXI CAN Interface Module with part number 780686-02?
Answer 3: To operate the National Instruments PXI-8511/2 PXI CAN Interface Module with part number 780686-02, one needs a CAN Breakout Box with part number 780041-01, two 1-meter long, 9-pin D-SUB female NI CAN No Termination Cables with part number 193128-01, and the module itself features two TJA1054A transceivers, supports a minimum baud rate of 40 kbits/s across its two
Question 4: What additional components are required for the operation of the National Instruments PXI-8511/2 PXI CAN Interface Module with part number 780686-02, and what are their specific part numbers?
Answer 4: The National Instruments PXI-8511/2 PXI CAN Interface Module supports a minimum baud rate of 40 kbits/s and requires the CAN Breakout Box with part number 780041-01 and two 1-meter long, 9-pin D-SUB female NI CAN No Termination Cables with part number 193128-01 for its operation.
Question 5: What are the necessary components and specifications required for operating the National Instruments PXI-8511/2 PXI CAN Interface Module with part number 780686-02?
Answer 5: For the operation of the National Instruments PXI-8511/2 PXI CAN Interface Module with part number 780686-02, one requires a CAN Breakout Box with part number 780041-01, and two 1-meter long, 9-pin D-SUB female NI CAN No Termination Cables with part number 193128-01.