img

PXI-8512

The National Instruments PXI-8512 PXI CAN Interface Module offers flexible data rates, supports CAN, LIN, FlexRay protocols, operates on Windows and LabVIEW Real-Time systems, and comes in variants with either 1 or 2 ports,

In Stock | Ships Today

img

    Description

    The National Instruments PXI-8512 PXI CAN Interface Module is a versatile and high-performance interface designed for networking applications using CAN (Controller Area Network) protocols, with part numbers 780687-01 and 780687-02 indicating models with either 1 or 2 ports, respectively. This interface module boasts a flexible data rate and supports a range of operating systems, including Windows and LabVIEW Real-Time, ensuring wide compatibility and integration with various software environments.

    With support for up to 192 hardware-accelerated frames, this module significantly improves system performance by reducing the load on the host system’s CPU. It is also compatible with multiple database engine formats such as FIBEX, CANdb (.DBC), LDF, and NI-CAN NCD, facilitating easy integration into existing network designs. Additionally, the RTSI synchronization support ensures precise timing and synchronization with other NI products, enhancing its functionality in complex systems.

    The NI PXI-8512 is not only versatile in its protocol support, which includes CAN, LIN, and FlexRay, but also in its physical deployment, supporting various form factors like PXI, PCI, NI CompactDAQ, and NI CompactRIO. This allows for seamless integration into a wide array of hardware setups, making it an ideal solution for a multitude of application scenarios.

    Feature Description
    Product Name National Instruments PXI-8512 PXI CAN Interface Module
    Part Numbers 780687-01 (1 port), 780687-02 (2 ports)
    Data Rate Flexible
    Interface Type CAN (Controller Area Network)
    Ports 1 or 2, depending on part number
    Operating Systems Windows, LabVIEW Real-Time
    Supported Protocols CAN, LIN, FlexRay
    Hardware-Accelerated Frames Up to 192
    Database Engine Formats Supported FIBEX, CANdb (.DBC), LDF, NI-CAN NCD
    RTSI Synchronization Support Yes
    Form Factors Supported PXI, PCI, NI CompactDAQ, NI CompactRIO

    Question 1: What operating systems are supported by the National Instruments PXI-8512 PXI CAN Interface Module for integrating with various software environments?
    Answer 1: The National Instruments PXI-8512 PXI CAN Interface Module supports operating systems such as Windows and LabVIEW Real-Time for integrating with various software environments.

    Question 2: What are the features and compatibility options of the National Instruments PXI-8512 PXI CAN Interface Module, considering its support for multiple protocols, flexible data rate, operating system compatibility, and synchronization capabilities?
    Answer 2: The National Instruments PXI-8512 PXI CAN Interface Module comes in two models, with the part number 780687-01 featuring 1 port and 780687-02 featuring 2 ports; its flexibility is evidenced by its support for variable data rates and compatibility with Windows and LabVIEW Real-Time operating systems, as well as RTSI synchronization, which enhances its integration capabilities with a broad range of software environments and ensures precise timing and coordination with other NI hardware systems.

    Question 3: What are the specific model numbers and corresponding port counts for the National Instruments PXI-8512 PXI CAN Interface Module, and how does its flexibility in terms of data rates, operating system support, and hardware synchronization enhance its compatibility with various software and hardware systems?
    Answer 3: The National Instruments PXI-8512 PXI CAN Interface Module features support for CAN, LIN, and FlexRay protocols, offers models with 1 or 2 ports with flexible data rates, and is compatible with Windows and LabVIEW Real-Time operating systems; it can handle up to 192 hardware-accelerated frames to reduce CPU load, supports database formats like FIBEX, CANdb, LDF, and NI-CAN NCD, and provides RTSI synchronization for precise timing with

    Question 4: How does the National Instruments PXI-8512 PXI CAN Interface Module ensure improved performance and CPU load reduction in networking applications?
    Answer 4: The National Instruments PXI-8512 PXI CAN Interface Module ensures improved performance and CPU load reduction in networking applications by supporting up to 192 hardware-accelerated frames, which offloads processing from the host system’s CPU, thereby enhancing system efficiency and responsiveness.

    Question 5: What features of the National Instruments PXI-8512 PXI CAN Interface Module contribute to its wide compatibility across multiple operating systems and network designs?
    Answer 5: The National Instruments PXI-8512 PXI CAN Interface Module’s wide compatibility across multiple operating systems and network designs is attributed to its support for a flexible data rate, compatibility with Windows and LabVIEW Real-Time, the ability to handle up to 192 hardware-accelerated frames, compatibility with various database engine formats such as FIBEX, CANdb (.DBC), LDF, and NI-CAN NCD, and RTSI synchronization, in addition to its protocol support for CAN, LIN