Description
The National Instruments PXIe-1082 PXI Chassis, with part numbers 780321-01 and 198666J-01L, is a high-performance, high-bandwidth equipment featuring an 8-slot PXI Express backplane that supports a maximum system bandwidth of 8 GB/s.
Designed to operate effectively in a wide temperature range, the chassis can function optimally between 0 to 55 °C for operating conditions, with a storage temperature range of -40 to 71 °C. To ensure durability and reliability, the chassis is built to withstand humidity levels of 10 to 90% non-condensing when operating and 5 to 95% non-condensing during storage.
The chassis is also equipped to handle both operating and non-operating random vibrations, with 0.3 grms during operation and 2.4 grms when non-operating, across a frequency range of 5 Hz to 500 Hz. Cooling is a strong suit for this chassis as it provides 38 W per slot of cooling capacity, ensuring that the system remains at an optimal temperature even under heavy load.
Even with its robust capabilities, the PXIe-1082 maintains a quiet acoustic emission of 43.6 dBA at temperatures ranging from 0 to 30 °C, making it suitable for environments where noise levels are a concern. Its physical dimensions are 6.97 inches in height, 10.69 inches in width, and 15.61 inches in depth, and it has a total weight of 19.4 pounds, striking a balance between space efficiency and structural integrity.
Question 1: What is the maximum operating temperature range of the National Instruments PXIe-1082 PXI Chassis, and how much cooling capacity does it provide per slot?
Answer 1: The National Instruments PXIe-1082 PXI Chassis operates within a temperature range of 0 to 55 °C and has a storage temperature range of -40 to 71 °C.
Question 2: What are the operational temperature range and maximum system bandwidth of the National Instruments PXIe-1082 PXI Chassis with part numbers 780321-01 and 198666J-01L?
Answer 2: The National Instruments PXIe-1082 PXI Chassis supports a maximum system bandwidth of 8 GB/s, and its operating and non-operating humidity levels are 10 to 90% non-condensing and 5 to 95% non-condensing, respectively.
Question 3: What are the operating and storage temperature ranges of the National Instruments PXIe-1082 PXI Chassis?
Answer 3: The maximum operating temperature range of the National Instruments PXIe-1082 PXI Chassis is 0 to 55 °C, and it provides a cooling capacity of 38 W per slot.
Question 4: What are the maximum system bandwidth and the supported temperature range for operating conditions of the National Instruments PXIe-1082 PXI Chassis?
Answer 4: The operational temperature range of the National Instruments PXIe-1082 PXI Chassis with part numbers 780321-01 and 198666J-01L is 0 to 55 °C, and it supports a maximum system bandwidth of 8 GB/s.
Question 5: What is the maximum system bandwidth supported by the National Instruments PXIe-1082 PXI Chassis, and what are its operating and non-operating humidity levels?
Answer 5: The National Instruments PXIe-1082 PXI Chassis supports a maximum system bandwidth of 8 GB/s and can operate effectively in a temperature range from 0 to 55 °C.
Specification | Details |
---|---|
Part Number | 780321-01, 198666J-01L |
Product Line | National Instruments PXIe-1082 PXI Chassis |
Backplane | High-bandwidth, 8-slot PXI Express |
Maximum System Bandwidth | 8 GB/s |
Operating Temperature Range | 0 to 55 °C |
Storage Temperature Range | -40 to 71 °C |
Operating and Storage Humidity Range | Operating: 10 to 90% non-condensing, Storage: 5 to 95% non-condensing |
Operating and Non-operating Random Vibration | 0.3 grms (operating), 2.4 grms (non-operating) |
Frequency Range for Vibration | 5 Hz to 500 Hz |
Cooling Capacity | 38 W per slot |
Acoustic Emission | 43.6 dBA at 0 to 30 °C |
Physical Dimensions (H x W x D) | 6.97 x 10.69 x 15.61 inches |
Weight | 19.4 lb |