img

PXIe-2746

The National Instruments PXIe-2746 is a PXI RF Multiplexer Switch Module with part number 780587-46, featuring 4 banks of 4 channels each, capable of handling RF signals up to 2.7 GHz,

In Stock | Ships Today

img

    Description

    The National Instruments PXIe-2746, with part number 780587-46, is a high-performance PXI RF Multiplexer Switch Module designed to manage RF signals up to 2.7 GHz across 4 banks, each containing 4 channels. This module offers versatile relay options including both electromechanical and FET relays, and features essential capabilities such as hardware triggering and relay count tracking to enhance test automation and reliability.

    It supports RF path calibration storage within NI Switch Executive, allowing for easy management of calibration data. The input characteristics can accommodate DC, AC, or a combination of both, ensuring a broad range of signal compatibility. With a maximum switching voltage of 30 V, a maximum RF power of 10 W, and both a maximum switching and carry current of 0.5 A per channel, this module is robust and versatile for various testing requirements.

    Operating efficiently, it requires only 3.96 W at 3.3 V and 0.2 W at 12 V, and is designed to function optimally within a temperature range of 0° C to 55° C, making it suitable for a wide array of environments. The PXIe-2746 is an excellent choice for complex and high-channel-count RF signal routing in production and test applications.

    Question 1: What are the electrical and thermal specifications of the National Instruments PXIe-2746 PXI RF Multiplexer Switch Module, including its power requirements, temperature range, and signal handling capabilities?
    Answer 1: The input characteristics of the National Instruments PXIe-2746 RF Multiplexer Switch Module can accommodate DC, AC, or a combination of both, and its power requirements are 3.96 W at 3.3 V and 0.2 W at 12 V.

    Question 2: What are the input characteristics and power requirements of the National Instruments PXIe-2746 RF Multiplexer Switch Module?
    Answer 2: The National Instruments PXIe-2746, part number 780587-46, is a PXI RF Multiplexer Switch Module that handles RF signals up to 2.7 GHz, contains 4 banks with 4 channels each, and offers relay options including electromechanical and FET relays; it also includes hardware triggering, relay count tracking, and RF path calibration storage, supports both AC and DC input signals, and has a maximum switching voltage of 30 V, a maximum

    Question 3: What are the electrical input characteristics and maximum power handling capabilities of the National Instruments PXIe-2746 RF Multiplexer Switch Module?
    Answer 3: The National Instruments PXIe-2746 PXI RF Multiplexer Switch Module has a maximum switching voltage of 30 V, a maximum RF power of 10 W, and a maximum switching and carry current of 0.5 A per channel; it operates efficiently with a power requirement of 3.96 W at 3.3 V and 0.2 W at 12 V, and is designed to function within a temperature range of 0° C to 55° C

    Question 4: What are the various relay options available for the National Instruments PXIe-2746 PXI RF Multiplexer Switch Module, and what are its key features that support test automation and reliability?
    Answer 4: The National Instruments PXIe-2746 RF Multiplexer Switch Module can accommodate electrical input characteristics of DC, AC, or a combination of both, and has a maximum RF power handling capability of 10 watts.

    Question 5: What are the key features and specifications of the National Instruments PXIe-2746 RF Multiplexer Switch Module, including its part number, frequency range, and relay options?
    Answer 5: The National Instruments PXIe-2746 PXI RF Multiplexer Switch Module offers versatile relay options including both electromechanical and FET relays, and its key features that support test automation and reliability include hardware triggering and relay count tracking.

    Feature Specification
    Part Number 780587-46
    Product Type PXI RF Multiplexer Switch Module
    Number of Banks 4
    Channels per Bank 4
    Maximum Bandwidth 2.7 GHz
    Relay Options Electromechanical, FET
    Hardware Triggering Yes
    Relay Count Tracking Yes
    RF Path Calibration Storage Yes, in NI Switch Executive
    Input Characteristics DC, AC, or both
    Maximum Switching Voltage 30 V
    Maximum RF Power 10 W
    Maximum Switching Current 0.5 A
    Maximum Carry Current 0.5 A
    Power Requirement 3.96 W at 3.3 V, 0.2 W at 12 V
    Operating Temperature Range 0° C to 55° C